  Purpose:X-ray scatter photons result in significant degradation of cone-beam CT(CBCT)image quality.Measurement based algorithms using beam block directly acquire the scatter samples and achieve significant improvement on the quality of CBCT image.In existing algorithms,single scan and stationary beam block design proposed before is promising due to its simplicity and practicability.Although demonstrated effectively on tabletop system,the block fails to correct for the shading artifacts induced by scatter on clinical CBCT machine mainly due to inaccurate scatter estimation from gantry wobble in the scan.In this work,we investigate the motion behavior of the beam block in each projection and estimate the variation of block trajectory from the gantry wobble.An accurate scatter estimation is then achieved from the wobble modeling and high-quality images are reconstructed from the corrected projections.Methods:A "crossing-finger" shaped block was mounted on the exit of the x-ray tube of a Varian onboard imager(Fig.1&2).To estimate the gantry wobble,we track the block in equal-angular distributed projections.Then the block trajectory is estimated using the measured trajectory samples by interpolation in each projection(Fig.3).The correction of gantry wobble was implemented in scatter estimation.Scattercorrected CT images are obtained using a modified half-fan reconstruction algorithm.Results:The proposed method is evaluated using Catphan@500 phantom.Using gantry wobble estimation,our approach reduces the reconstruction error from 86 Hounsfield unit(HU)to 15 HU in the selected regions of interest(Figs.4&5),and improves the image contrast by a factor of 1.3 in the high-contrast regions(Table I).Conclusions:In this work,we propose a practical scatter correction solution with gantry wobble estimation for clinical CBCT system.The method is practical and attractive for CBCT guided radiation therapy.
其他文献
Purpose:To Time-of-Flight positron emission tomography(TOF-PET),the TOF benefit highly depends on the system timing precision.As a result,it is meaningful to measure the time resolution of the PET sys
Purpose:We study the dosimetric effect on the target volume,organs at risk(OARs)and normal tissues based on the different choice for four types of variables,namely,treatment position,dose calculation
Purpose:In this paper,we report the results of our investigation into whole brain radiotherapy(WBRT)using linear accelerator(Linac)-based intensity-modulated radiation therapy(IMRT)and volumetricmodul
Purpose:Abdominal compression is known to be effective but,often makes external-marker-based monitoring of breathing motion not feasible.In this study,we developed and evaluated a system that enables
会议
Purpose:To develop a patient-specific rectal toxicity predictor guided plan quality control tool for prostate SBRT plans.Methods:For prostate SBRT cases,rectal wall is identified as organs at risk and
The purpose of this study was to conduct quality assurance(QA)of plans of four patients having multiple metastatic lesions(targets)simultaneously treated with mono isocentric three dimensional conform
Purpose:This study aimed to determine the optimal fractions scheme(FS)in small peripheral non-small cell lung cancer(NSCLC)patients undergoing stereotactic body radiotherapy(SBRT)by comparing the ther
Purpose To explore the real-time dose verification method in volumetric modulated arc radiotherapy(VMAT)with a 2D array ion chamber array.Methods The 2D ion chamber array was fixed on the panel of ele
Purpose:The most common type of cancer among women is breast cancer.Accurate assessment of skin dose in radiotherapy can provide useful information for clinical consideration.The aim of this study is
Purpose:A novel breathing guidance method by combining the personalized audio-visual biofeedback(BFB)system,the breath hold(BH)method,and the synchrotron-based gating technique was developed to help p