【摘 要】
:
With the current emphasis on green energy,many studies are now focusing on energy savings in terms of indoor air quality.If indoor air is not kept within reasonable limits,then it may lead to illness
【机 构】
:
Department of Refrigeration,Air Conditioning and Energy Engineering,National Chin-Yi University of T
【出 处】
:
2016冷冻空调亚洲大会(8th Asian Conference on Refrigeration and Air-c
论文部分内容阅读
With the current emphasis on green energy,many studies are now focusing on energy savings in terms of indoor air quality.If indoor air is not kept within reasonable limits,then it may lead to illness and other issues of mutual infection when a patient undergoing registration,diagnosis,and prescription travels from the registration area to the waiting area and stays in the hospital from 1 hr to 2 hrs,or even longer.The hospital premises need clean fresh air.In this study,hospital indoor air CO2 concentration analysis is conducted by using computational fluid dynamics analysis tools to simulate the regional hospital drawing model,analyze the regional distribution of temperature and CO2 concentration in the hospital,and set the outside air through the vents.
其他文献
This paper is focused on design,analysis,fabrication and tests of a high-power and high-speed motor for adopting in a centrifugal compressor with an AMB.A novel approach for retaining the PMs of the r
The functional formula of the flow coefficients for the radial clearance in a rolling piston rotary compressor was developed by the experiments and Computational Fluid Dynamics(CFD)to improve the accu
Energy conservation is one of the vital issues of the present,and the reuse of discarded energy is a highly recommended method for saving energy.In this study,a heat pump–boiler integrated system was
A linear compressor for a domestic refrigerator-freezer has energy saving potential compared with a reciprocating compressor because of a low friction loss and free piston system.A linear compressor c
This study we developed a design procedure for the 5.5kW oil-free air scroll-compressor with prototype processing and test verification.Through the fundamental geometry information about scroll profil
This paper presents an analysis for the dynamic behavior of a linear compressor having a piston driven by electromagnetic force of Linear Oscillating Actuator(LOA).Linear compressor compresses gasses
A child with the flu,diphtheria,meningitis,hand,foot and mouth diseases,measles,cough and pneumonia with one coughs can generate airborne contaminant.In addition to infectious agents and other emissio
The efficiency and pressure drop of oil separator with various MFR(mass flow rate),LCR(liquid circulation ratio),and heights of discharged pipe(outlet pipe)are investigated.The lubricant oil in compre
In hospitals,both the occupant density and the population flow are large,which results in the variety of pollutants in the air environment.This brings about challenge for control measures of hospital-
Most drivers in Taiwan usually close the window and set ventilation at full recirculation mode to lower the concentrations of particle pollutants in cabin.However,such driving habits often result in a