通过对以往灰库实际工程量的比较,进行壁厚的方案优选,并结合灰库计算过程中的难点温度应力计算,提出计算方法,以期后续工程筒仓计算更加精确,达到经济安全的目的.考虑温度应力的计算在以往的计算手册中都是基于经验,现依据《民用建筑热工设计规范》GB50176-93并结合实际工程,以内部贮料温度为100°C、室外极端温度为-25°C为例,根据《钢筋混凝土筒仓设计规范》和《火力发电厂除灰设计规程》进行计算.
Based on the comparison of the actual engineering quantities of the former gray silos, the scheme of the wall thickness is optimized and the calculation of the temperature stress in the process of calculation of the gray silo is proposed. The calculation method is put forward in order to achieve the goal of more precise silo calculation in subsequent projects and economic security. Considering the calculation of temperature stress in the past are based on the calculation of manuals are based on “Civil Engineering Thermal Design Code” GB50176-93 and the actual project to the internal storage temperature of 100 ° C, the outdoor temperature is -25 ° C as an example, according to “Code for Design of Reinforced Concrete Silos” and “Code for Desulphurization Design of Thermal Power Plants”.