The impact of plan complexity parameters on the plan quality and deliverability of volumetric modula

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:dongshantongak
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose:To evaluate the impact of complexity indices on the plan quality and deliverability of the volumetric modulated arc therapy(VMAT),and to determine the most significant parameter in the development of an ideal clinical VMAT plan.Methods:A multi-dimensional exploratory statistical method-canonical correlation analysis was adopted to study the correlations,as well as the contribution weights,of treatment plan parameters of complexity,quality and deliverability for 32 nasopharyngeal cancer with two-arc VMAT plans and 31 esophageal cancer patients with one-arc VMAT plans.Results:The average PTV volumes of NPC and esophageal cancer patients were 826.4±203.9,and 662.4±271.8 cm 3,respectively.The average total MU of two-arc NPC patients were 672.3±54.4 versus 538.1±87.5 of one-arc esophageal caner patients.MU per arc(MU/ARC)and MU per control point(MU/CP)of NPC were 337.8±25.2 and 3.7±0.3,respectively,which were significantly lower than those of esophageal cancer patients(MU/ARC :475.0±100.0,MU/CP :5.2±1.1); The proportion of MU/CP less than 3 was higher and the proportion of SA less than 50 cm 2 was lower in the NPC groups compared with esophgeal cancer patients.The average segment area of control points(SA/CP)of NPC patients were larger than(p=0.013)those of esopageal cancer(66.3±9.4 vs.58.1±15.4 cm 2).MCSv per arc of NPC was lower than that of esophageal cancer patients.All these plan complexity indices indicated that two-arc VMAT plans of NPC were more complex than one-arc VMAT plans of esophageal cancer patients.Canonical correlation analysis indicated that plan complexity parameters were highly correlated with plan quality,but not with deliverability,in which MU/CP and MU/ARC were contribute the greatest weights.Conclusions:We have quantified various plan characteristics in terms of complexity,quality,and deliverability.MU/CP and MU/ARC were found to have strong effect on the plan quality,but not on deliverability.New robust deliverability parameters instead of relative gamma passing rate should be investigate for further study.
其他文献
  Purpose:Parotid gland tumors account for 3%of head and neck tumors.Adjuvant radiotherapy is suggested for reducing the risk of high grade parotid tumors.The
会议
  Purpose The purpose of this paper is to compare the dosimetric characteristics of protection of hippocampus between VARIAN RapidArc(volumetric modulated arc
会议
  purpose To compare the dosage of target regions and bone in three-dimensional(3D)brachytherapy and two-dimensional(2D)Paris system brachytherapy for soft ti
会议
会议
  Objective To study the intensity modulated rotary volume plan in the esophageal carcinoma radiotherapy.Methods Application of 0.6 cm3 finger ionization cham
会议
  Purpose:The most common type of cancer among women is breast cancer.Accurate assessment of skin dose in radiotherapy can provide useful information for clin
会议
  Purpose:To quantify the advantages in prescription dose escalation from helical tomotherapy(HT)compared to LINAC-based IMRT on nasopharynx cancer.Material a
会议
  Purpose:This study aimed to determine the optimal fractions scheme(FS)in small peripheral non-small cell lung cancer(NSCLC)patients undergoing stereotactic
会议
  Real-time monitoring of ablation effect,temperature distribution and ablated area in the tumor treatment is a core problem in microwave thermal ablation.Thr
会议
会议