A SD reconstrction algorithem based on toast for fluorescence diffuse optical tomography

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:nokisoki
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Purpose The 3-D reconstruction of the fluorescence yield is achieved by using a method that main interest is its ability to reconstruct the fluorescence distribution in media presenting heterogeneous optical properties and high attenuation defined by k2=3μaμs.The reconstruction is performed according to two main steps:attenuation reconstruction,then fluorescence reconstruction.
其他文献
Purpose:Collapsed-cone convolution/superposition(CCCS) dose calculation algorithm is typically used for IMRT dose calculation in most commercial treatment planning systems(TPS).The purpose of this pap
会议
Purpose:To evaluate a Hybrid IMRT/VMAT technique which combined intensity modulated radiotherapy(IMRT)and volumetricmodulated arc therapy(VMAT)as a treatment option for the radiotherapy of nasopharyng
Purpose:Treatment plans with non-coplanar beams have shown promise for the better dose avoidance of normal organs,which is favorable for stereotactic body radiation therapy(SBRT).The purpose of this p
会议
Purpose:To develop and evaluate an effective real-time tracking and gating radiotherapy based on dMLC for mobile tumor.Methods:A novel technology has been proposed for mobile tumor radiotherapy,where
Purpose:To develop a pencil beam algorithm(PBA)for dose calculation of proton beams in both homogeneous and heterogeneous media.Methods:The proton PBA consisted of the integral depth-dose and the off-
Purpose:In IMRT QA,plan quality evaluation is made based on pass rate under preset acceptance criteria,mostly using gamma-values.This method is convenient but,its result highly depends on what the acc
会议
Purpose In IMRT QA,the geometric errors(GE),which differences between the reference and measured dose distribution caused by a rotation and shift of a dose distribution because of QA environment setti
会议
TOPAS is a newly developed Monte Carlo simulation tool that combines extensive radiation physics libraries available in Geant4 code and easy-to-use geometry and visualization features.Although TOPAS h
The single source channel of Leksell Gamma Knife was simulated using Monte Carlo N-Particle Transport Code System(MCNPX version).The accurate dose distribution in a water-equivalent sphere phantom of
Medical Physics research contributions have been dominated by development of conformal treatment delivery technologies along with planning,imaging,and dose prediction tools that support accurate deliv
会议