Real-time patient transit dose verification of volumetric modulated arc radiotherapy by a 2D ionizat

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:absyou
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose To explore the real-time dose verification method in volumetric modulated arc radiotherapy(VMAT)with a 2D array ion chamber array.Methods The 2D ion chamber array was fixed on the panel of electronic portal imaging device(EPID).Source-detector distance(SDD)was 140cm.8mm RW3 solid water was added to the 2D ion chamber array to improve the signal noise ratio.Patient plans for esophageal,prostate and liver cancers were selected to be delivered on the cylindrical Cheese phantom 5 times in order to validate the reproducibility of doses.Real-time patient transit dose measurements were performed at each fraction.Dose distributions were evaluated using gamma index criteria of 3mm DTA and 3%dose difference referred to the first time result.Results The gamma index pass rate in the Cheese phantom were about 98%; The gamma index pass rate for esophageal,prostate and liver cancer patient were about 92%,92%and 94%,respectively; Gamma pass rate for all single fraction were more than 90%.Conclusions The 2D array is capable of monitoring the real time transit doses during VMAT delivery.It is helpful to improve the treatment accuracy.
其他文献
  Introduction:Cardiac T2* becomes a standard method to assess iron accumulation in myocardium.The reliability of T2* during the course of a longitudinal stud
会议
  Purpose:Sparse-view computed tomography(CT)reconstruction without significantly degrading image quality is an important issue in medical imaging domain.Non-
会议
  Purpose :The purpose of this study is to compare dosimetric differences during radiation treatment in patient with breast cancer between prone position vers
会议
  Methods:The records cervical cancer patients with squamous cell carcinoma(stage IB to IVA)underwent definitive radiotherapy in year 2009-2013 were retrospec
会议
  This study aimed to compare estimates of secondary cancer risks using five radiotherapy modalities to treat breast cancer:intensity-modulated radiotherapy(I
会议
会议
  Purpose:Few-view CT can reduce the radiation delivered to patients,and total variation(TV)based iterative reconstruction methods have potential to reconstru
会议
  objective by measuring the VARIAN IX and 23 EX medical linear accelerator for 60 and 40 to dynamic multileaf collimator(DMLC)transmission between doses,leaf
会议
  Background:A conversion from computed tomography(CT)values obtained using single-energy CT to relative electron density(RED)for water or mass density(MD)is
会议
  Purpose:Radiochromic EBT3 film is a later generation of radiochromic films.The aim of this study is to compare EBT and EBT3 radiochromic films in radiothera
会议