Development of high temperature high pressure electrochemical measurement electrode device and verif

来源 :第三届核电厂材料与安全可靠性国际研讨会 (3rd MRNPP Symposium) | 被引量 : 0次 | 上传用户:dragoonzj
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Electrochemical measurement electrode device for large scale facility service is developed.With start-up and shutdown process during verification test,304SS electrochemical corrosion potential(ECP)response is successfully on-line measured.The results indicated that ECP for 304SS first reduced,then plateaued and finally increased.In the plateaued stage,the ECP for 304SS is 0.26VSHE and the measured value is duplicated.The device design and preliminary on-line monitoring test provides some guidance on its practical engineering application.
其他文献
Characterizations of the microstructure and chemical composition of oxide films formed on 316NG stainless steel following exposure experiments in high temperature water with various dissolved hydrogen
会议
Stress corrosion cracking(SCC)of sensitized 304 stainless steel(SS)in borated and lithiated high temperature water without and with Zn injection was studied using slow stain rate test(SSRT)and surface
This paper introduces a new test model and data acquisition plan for evaluation of materials of thin-walled tubes of nuclear power plant.In analogy to crack growth rate measurements using compact tens
The microstructure and distribution of residual strains were investigated in the fusion boundary region of domestic low alloy steel SA-508Ⅲ weld joint using scanning electron microscope(SEM),electron
The water environment of pressurized water reactor is high pressure and high temperature,meanwhile,in order to protect steam generators,the water chemistry in the secondary loop of PWR is required to
会议
Crevice corrosion is one of the most common localized attacks,which always occurs within the occlude regions or under shielded metal surfaces.Materials relying on passive surface films for corrosion r
会议
To a large extent,the reliability of nuclear structures depends on the mechanical properties of the constituent materials which work at elevated temperatures under a high radiation environment.Usually
会议
Alloy 690 is widely used as steam generator heat transfer tube in PWR nuclear power plants.During the process of heat exchange,the thin tubes are subjected to vibration,i.e.,flow induced vibration.Man
会议
304 stainless steel,316L stainless steel and 316NG stainless steel are conventional materials of primary pipe in nuclear power plants.The present work is to summarize the acoustic emission(AE)characte
The electrochemical measurement is a promising method available to perform actual continuous in-situ monitoring of corrosion degradation in nuclear power plants.The tungsten/tungsten oxide electrode w