论文部分内容阅读
本文对以氯化锂为吸湿剂的吸附除湿空凋系统进行了实验研究,实验结果表明:该空调系统再生空气的最佳温度为90℃;空调工况下制冷系数COP在41-51%之间;如果再生空气温度低于80℃,则COP低于20%。并且还讨论了该空调系统各个操作参数之间的相互关系。本文取得的实验数据为吸附除湿空调系统的进一步完善提供了可靠依据。
In this paper, an experimental study on adsorption desiccation and air-wasting system using lithium chloride as a moisture absorbent has been carried out. The experimental results show that the optimum temperature of regeneration air for the air-conditioning system is 90 ℃ and the COP of the air-conditioning system is 41-51% If the regeneration air temperature is below 80 ° C, the COP is below 20%. The relationship between the various operating parameters of the air conditioning system is also discussed. The experimental data obtained in this paper provide a reliable basis for the further improvement of adsorption desiccant air conditioning system.