固定床吸附器水蒸气解吸过程研究

来源 :化学工程 | 被引量 : 0次 | 上传用户:annhongmay
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
针对低浓度甲苯活性炭固定床吸附 ,对水蒸气解吸载甲苯活性炭固定床作了实验和理论研究 ,测定了水和甲苯在直径 5 0 0 mm,高 15 0 0 mm的固定床中的分布。活性炭取样点在轴向上七个点采样 ,活性炭中甲苯及水含量用 Karl Fisher法测量。活性炭在 15 0℃ ,5 0 Pa条件下解吸。建立了适用于模拟固定床水蒸气解吸的均相模型 ,并对实验结果进行模拟计算 ,结果表明 ,所建模型与实测结果能很好吻合 Aiming at the adsorption of low concentration toluene on activated carbon fixed bed, experimental and theoretical study on the fixed bed of activated carbon loaded with water vapor was carried out. The distribution of water and toluene in fixed bed with diameter of 500 mm and height of 150 mm was measured. Activated carbon sampling points were sampled at seven points in the axial direction. Toluene and water contents in activated carbon were measured by the Karl Fisher method. Activated charcoal is desorbed at 150 ° C and 50 Pa. A homogeneous model suitable for simulating water vapor desorption in a fixed bed was established and the experimental results were simulated. The results show that the model is in good agreement with the measured results
其他文献
期刊
红外焦平面成像系统是红外成像技术发展的趋势,焦平面阵列的非均匀性校正技术是一项正在探索的关键技术。在分析了红外成像系统非均匀性的产生机理及表现特征的基础上,介绍了
目的 观察稳心颗粒治疗尘肺并发肺心病的疗效.方法 对118例尘肺并发肺心病的患者口服步长稳心颗粒治疗,每次1包(9 g),3次/d,并对临床症状、心电图、动脉血氧分压进行观察.结
动态累积操作是提高分批精馏效率的一种有效方法 ,但在塔顶累积罐内存在的液相返混限制了分离效率的进一步提高。本文提出了塔顶累积罐无返混动态累积操作过程。研究了塔板和
期刊
期刊
详细介绍了多相催化加氢数学模型回归的计算方法。对无副反应存在下数学模型可以处理成为线性模型进行简化,从而求得参数。但该法直接使用的dCdt值,是使用作图镜面法获得,会
多发性骨髓瘤(MM)是浆细胞系统的一种恶性肿瘤,在老年人中发病率较高,严重危害人类健康,因此,需要找到更新、更安全的治疗措施来提高治疗效果,延长疾病的稳定期和提高总体生
应用空气-水系统,在直径φ600mm的塔内,对微分浮阀塔板的流体力学进行了实验研究,测定了临界孔速、塔板压降、雾沫夹带率和液体泄漏率.应用空气-水-氧气物系,测定了微分浮阀