以某写字楼为例 ,分析了变风量系统中不同分区形式对各朝向房间的人均新风量分配的影响 ,认为新风量分配不均的情况主要出现在冬季和过渡季 ,提出满足所有朝向房间人员健康要求同时能实现过渡季利用新风节能的新风量设计标准 ;建议在建筑设计中增加新风竖井面积 ,在空调外区适当增加最小新风量的取值。
Taking a office building as an example, the influence of different subareas in the variable air volume system on the distribution of fresh air volume per room is analyzed. It is considered that the uneven distribution of fresh air volume mainly occurs in the winter and transitional quarters, Requirements at the same time be able to achieve the transition season, the use of fresh air energy efficiency of the new air volume design standards; proposed in the architectural design to increase the area of fresh air shaft, air conditioning outside the appropriate increase in the minimum amount of fresh air value.