鞍钢7#、11#高炉(2580m3)脱水器为110kW单电机驱动。几年来,通过生产实践考察和参数分析计算,电机110kW偏大,脱水器在生产运行过程中还存在一些缺点,需要改进。功率是脱水器非常重要的基本参数,零部件的选择计算都要以功率参数为依据。为了使鞍钢新建5#高炉脱水器具有优越的性能,对脱水器功率进行分析计算。为验证分析计算的正确性,采用了两种计算方法,其结果两种方法的数据基本一致。通过分析计算成果将单电机改为双电机加液力耦合器传动方案,实现脱水器软启动。经一年多生产实践考核,不仅节约了电能,且证明计算是正确的,改进是成功的。
Anshan Iron and Steel 7 #, 11 # blast furnace (2580m3) dehydrator 110kW single motor drive. Over the past few years, through the production practice inspection and parameter analysis and calculation, the motor 110kW is too large, dehydrator in the production and operation of the process there are still some shortcomings need to be improved. Power is a very important basic parameters of the dehydrator, the choice of components must be based on the power parameters. In order to Anshan Iron and Steel 5 # BF dehydrator with superior performance, dehydrator power analysis and calculation. To verify the correctness of the analysis and calculation, two calculation methods are used, and the results are basically consistent with the data of the two methods. By analyzing and calculating the result, the single motor was changed to the double motor plus hydraulic coupler transmission scheme to realize the dehydrator soft start. After more than a year of production practice assessment, not only saves power, and proved that the calculation is correct, the improvement is successful.