以实际工程为背景,建立4层冷弯薄壁型钢结构住宅有限元模型,参照抗震设计规范要求对模型进行双向动力时程分析,研究该住宅体系的抗震性能,为编制《冷弯薄壁型钢多层住宅技术规程》提供可靠依据。对相邻抗侧力墙体之间的距离进行变参数分析,研究在多遇地震作用下4层冷弯薄壁型钢结构住宅各层墙体分配层间剪力的比例关系,分析刚性楼盖假设在多层冷弯薄壁型钢住宅中的适用性。研究表明:在8度多遇地震作用下,多层住宅体系中抗侧力墙体的间距不宜大于15m。
Taking the actual project as the background, a finite element model of four-story cold-formed thin-walled steel structure residential building is established. According to the requirements of the code for seismic design, two-way dynamic time history analysis of the model is carried out to study the seismic performance of the residential system. Multi-storey residential technical regulations "to provide a reliable basis. The variable parameters of the adjacent anti-side-wall were analyzed to study the proportional relationship between the shear forces distributed among the walls of four-story cold-formed thin-wall steel structure residential buildings in the event of frequent earthquake. Assuming applicability in multi-story cold-formed thin-walled steel houses. The results show that under the effect of earthquakes of more than 8 degrees, the spacing of anti-lateral walls in multi-storey residential buildings should not be more than 15m.