论文部分内容阅读
This paper analyses the changing rule of indoor ozone concentration and its influencing factors. A for-mula of indoor-outdoor concentration ratio(I/O ratio)was deduced based on the indoor ozone mass-balance equa-tion. The ozone I/O ratio in different kinds of buildings was studied. Results show that I/O ratio is much related to air-exchange rate, which is well compatible with the theoretical calculation results.