论文部分内容阅读
首先针对千岛湖景区的气候条件、水质条件以及千岛湖景区集中空调系统的应用现状做了分析,发现在千岛湖景区具备良好自然条件,可以采用双冷源温湿耦合的空调系统。其次分别研究了适用于千岛湖景区的双冷源温湿耦合空调系统的冷源、输送系统和末端空气处理过程的工作原理。最后,得到了千岛湖景区关于双冷源温湿耦合空调系统的冷源、输送系统及末端空气处理过程的设计计算方法,该设计计算方法适用于采用自然冷源作为高温冷源的双冷源温湿耦合的空调系统。
First of all, according to the climatic conditions, water quality conditions and the current situation of the central air-conditioning system in Qiandao Lake Scenic Area, the paper finds that Qiandao Lake Scenic Area has good natural conditions and can adopt the dual-source air-conditioning system. Secondly, the working principle of cooling source, conveying system and end air treatment process of double-cooling source temperature-humidity coupling air-conditioning system are studied respectively for Qiandao Lake Scenic Area. Finally, the design and calculation method of Qiandaohu scenic spot about the cooling source, conveying system and terminal air treatment process of the dual-temperature source air-conditioning system is obtained. The design and calculation method is applicable to the dual cooling source which uses the natural cold source as the high temperature cold source Temperature and humidity coupled air conditioning system.