一、概况 1986年元月份,架修好的240号机车投入运用。走行12750km后,在运行途中主发电机大线着火,18根大线全部烧毁,主整流柜有局部烧损。由于当时使用了泡膜灭火器,已把现场破坏,看不出火是由哪些部位引起的。通过分析,认为是由于线鼻子没有压紧所致(因架修时换过两根大线)。处理时,简单地更换了大线及相应的烧损部件,并于同年2月份配属古冶机务段。在古冶段运行一万多公里后,运行途中又发生了着火
I. Overview In January 1986, the No. 240 locomotive repaired was put into operation. After running 12,750km, the main generator on the way to run on fire, 18 lines were destroyed, the main rectifier cabinet has a local burn. As the bubble fire extinguisher was used at that time, the scene had been destroyed and it was impossible to see which parts of the fire were caused by it. Through the analysis, that is due to the line nose is not due to compression (due to repair replaced two large lines). Treatment, the simple replacement of the line and the corresponding burning parts, and in February the same year, assigned to the ancient rule of the locomotive depot. After the operation of more than 10,000 kilometers in Guye section, there was a fire on the way of operation