论文部分内容阅读
This study examined the cytotoxicity of a new implant material modified by microarc oxidation technique. Cells on different surfaces of the implant were evaluated 2, 4 and 6 days after treatment. The results showed that cell attachment, cell morphology, and cell proliferation were influenced by the different surface treatments, and a significant increase in the osteoblast cell activity was observed on the porous MAO-Ti coating. Our results suggest that the porous MAO-Ti surface has a better biocompatibility and electrochemical performance than pure titanium surface.