黄骅港是西煤东运第二条大通道的出海口,其装卸设备现代化程度在国内居于领先地位,变频调速作为一种高效节能的电机调速装置在黄骅港煤炭装卸设备中得到了广泛的应用。富士变频器因其操作简单实用、运行可靠而在我港的装卸设备中被大量的采用。随着时间的推移,富士变频器也渐渐进入故障高发期,如何能快速找到故障原因并排除故障成为亟待解决的问题,通过4年来对富士变频器的现场维护经验,下面就富士变频器在我港装卸设备中出现的一些常见故障及维修对策和大家作一个探讨。富士变频器经过近20年的发展无论是在机器外形体积上,还是在线路板新器件的应用上以及元器件的集成度上,都有了长足的发展,新产品更是不断推陈出新,从早期的2系列
Huanghua Port is the second largest passageway to the east of western China. Its port has a leading position in terms of the modernization of handling equipment. As a high-efficient and energy-saving motor speed control device, Huanghua Port has gained extensive popularity in Huanghua Port coal handling equipment. Applications. Fuji inverter because of its simple and practical operation, reliable operation and handling equipment in our port has been a lot of use. With the passage of time, Fuji inverter has gradually entered the high incidence of failure, how to quickly find the cause of the malfunction and troubleshooting has become a pressing issue, through four years of Fuji inverter field maintenance experience, the following on the Fuji inverter in me Port handling equipment in the emergence of some common faults and maintenance measures and we make a discussion. Fuji inverter after nearly 20 years of development, both in the shape of the machine size, or in the application of new circuit board components and components on the degree of integration, have made considerable progress, the new product is constantly evolving, from the early 2 series