论文部分内容阅读
摘 要:随着国民经济发展越来越好,人们的生活水平也随之不断提高,自然而然对于住宅建筑的要求也越来越高了。随着各类住宅建筑大量涌现,也使建筑给排水技术得到了较快发展。然而,随着给排水工程的增多,也出现了一些需要注意的问题,如果处理不好,会给使用者带来很多不必要的麻烦。给排水工程对住宅建筑整体功能的实现具有十分重要的意义。如果住宅建筑中给排水工程存在问题,那么将会直接影响住户的居住感受。本文做了一系列的探讨。
关键词:建筑给排水;水表设置;设计方案
Abstract: along with the development of the national economy more and better, the living standard of people also will improve, for residential construction requirements naturally more and more is also high. All kinds of residential building with a rash also make the building water supply and drainage technology has been developed rapidly. However, with the increase of water supply and drainage engineering, there arise some problems that should be paid attention to, if treatment is not good, will give the user to bring a lot of unnecessary trouble. Water supply and drainage engineering on the realization of the whole function of residential buildings have very important significance. If residential building water supply and drainage engineering problems in, so will directly influence the living feelings of the residents. This paper made a series of discussion.
Key Words: building water supply and drainage; the water meter set; design scheme
中圖分类号:S276文献标识码:A 文章编号:
为了满足住户舒适、美观的要求,在设计工作中要综合考虑各方面的因素,完善施工技术,为住户营造一个美观实用的居住环境。
1、住户给水进户管径的确定
很多住户供水管道距离比较长,为了避免供水管道中产生噪音以及供水点水流不足等情况发生,一定要根据室内的实际情况来选择合适的供水管理直径,并控制好供水压力,从而确保用户用水的方便。一般来说,住宅用户的主要的用水点大多都是集中在厨房和卫生间,一厨一卫可以选择DN25(DN20)的管道,一厨多卫需用DN32(DN25)的管道,以满足使用要求。
2、适当增设单体建筑户外控制阀门
以往的住宅给水设计中,几个楼群共同使用一个总的控制阀门,而每户入户的管道设置一个阀门,这是十分必要的,一旦用户室内供水出现问题,可以及时的关闭阀门,从而防止问题进一步的扩大化。而在整个住宅小区的范围之内应该适当的增加阀门的数量,这样出现供水问题的时候能够及时切断供水,方便进行维修。这样可以减少阀门关闭时对于其它用户用水带来的干扰。笔者认为以停水范围不超过100户时设室外总控制阀为好。
3、注意室外阀门的安装型式
室外安装的阀门大部分都是口径为DN75以上的闸阀,问题是这些装于地下的阀门一旦损坏时如何更换。埋于地下的管道没有多少伸缩的余地,更换阀门时很难塞进法兰垫片,常常要挖地坑和割管子,费时费力,停水时间长。设计时仅需在每一个连接阀的管道处设一个伸缩器则可以较好地解决这一问题。这一点,教科书和规范上都没作规定,却十分实用,且投资不多。
4、地漏与存水弯的配合
凡是室内承接有粪便污水的排水系统的地漏,均应配套存水弯,此可有效地防止串味现象。
5、室内排水管最小管径
一般来讲,污水池、小便器等器具的排出管最小管径为 De50,而含有粪便污水的最小管径为 De110。通过观察后认为这种规定只适用于楼面排水,而不适用于地面排水。原因如下:De50 的管径较小,容易堵塞,且不易疏通。在楼面上排水管系统尚有楼面下管道清扫口可用,而在地面上的小排水管堵塞时,则往往要扒开地面方能维修。笔者的经验是,在地面以下敷设的排水管最小管径宜为DN75,那样并不需要多增加多少投资,也不占用使用空间,但却方便使用和维修。对于楼房粪便污水的底层排出横管,使用 De160 为最小管径更适合中国国情。一般这段横管长度不大,由 De110 改为De160 也不会增加很多投资,但却能极大地减少管道的堵塞机会。而改变管径位置宜设在立管地面以下的地方,这样并不影响地面以上的空间。
6、水表的设置
水表是建筑给排水工程中的一个重要的组成部分,是对用户用水量进行核算的重要的依据,同时能够减少水资源的浪费。传统的水表都是安装在用户的家中,这就使得每次查表都要进入用户家中,给用户的生活带来不便,也使住宅私密性及安全性得不到很好保障,同时也增加了查表人员的工作难度和工作量。针对这种情况,现在一般都把水表设置在用户室外,从而方便进行管理。
6.1 水表集中设置在首层
多层住宅,可将用户的水表安装在建筑的首层的水表箱之内,将供水管道安装在楼梯间内。对于南方地区的一些住宅由于冬天气温较高即使水管直接设置在室外也不用担心被冻裂,可以直接将水表设置在首层的室外,沿着外墙进行用户供水支管的铺设。并宜在进户处设阀门,以便户内管道或龙头损坏漏水能及时关闭。
6.2 水表分别集中设置
在高层建中,水表一般分别集中设置在每层水管井内。但要考虑观察方便。
6.3 分户远传水表的设置
与水表出户不同,分户远传水表是安装在用户室内的,可以设置在卫生间之内等尽量靠近用水点的地。这种水表虽然安装在室内,但是由于其采用先进的科技可以直接实现与该住宅小区的水表管理系统相连,由远程的计算机直接记录水表的读书,不需要进户进行人工抄表极大的减少了工作人员的劳动量,同时提高了抄表的效率,能够及时的收缴水费。缺点是造价高,在物业管理完善的中高档商品房住宅小区可采用远传水表,它是今后水表应用发展的方向。
除了可以使用远传水表之外,一些新兴的住宅小区还可以采用 IC 卡水表,用户可以实现预付费购买一定量的水,然后才可以使用,这样可以有效的减少用户拖欠水费的行为,同时也方便收费。这两种水表都是高科技在供水中的应用,极大的改变了传统意义上的水表管理。
随着人们生活水平的不断提高,这两种水表将会有更加广阔的发展空间。
7 、排水横管的敷设
《住宅设计规范》早就要求;污废水排水横管宜设置在本层套内。这样排水横管渗透时可避免污水进入邻户,管道维修时也不会影响到邻户的正常生活。即使管道有安装和使用问题,也可以很轻易地在本层户内解决。据此产生了同层排水系统。同层排水系统主要有二种不同的方式:一是降板:即采用卫生间楼板(或局部楼板)下层的方式;二是墙排(以管道隐弊安装系统为主要特征)方式。墙排因卫生器具的选择余地较小,地漏难以设置等原因,适用范围较小,在此不展开。
7.1 降板同层排水
降板同层排水是将卫生间结构楼板下沉(局部)200~350mm作为管道敷设空间,污水横管设于下沉室内。这种方式对排水管道的施工较为方便。在使用过程中,经常发生下层住户靠卫生间楼板及侧墙发生渗漏现象。产生渗漏的主要原因有:卫生间地面防水处理不好,地面水渗透到下沉室;部分排水管道漏水进入下沉室,这是降板同层排水最大的缺点----回填层内可能积水。针对以上原因目前采取的措施有:严格做好卫生间地面的防水处理及下沉室四周的防水处理;下沉室内所有排水管道应经严格试压住水试验后方可回填。并在下沉室侧面设置侧排地漏(排水器),以排除可能出现的积水。可地漏(排水器)现行的做法都是接在排水管上,这样有可能排水管的臭气会进入回填层,解决办法是:地漏(排水器)等单独設立管排,且底部间接排放。8、总结
建筑给排水系统与我们的日常生活息息相关,一些设计施工中的细节处理不细致,常常给住户带来诸多问题,设计人员,应本着安全、美观、实用、经济的原则,在实践中努力创新,将问题消除于萌芽状态。
参考文献
[1]宋百盛.浅议建筑给排水系统施工中的若干通病[J]广东科技,2006(5).
[2]张如心.住宅工程水暖系统质量通病及防治[J]山西建筑,2004(24).
[3]陈永科.建筑给排水施工中的问题探讨[J]建材技术与应用,2009(2).
[3]《国家标准建筑给水排水设计规范》GB50015-2003. 2009年版北京.中国计划出版社.2010.
[4] 《国家标准住宅设计规范》GB50096-2011.北京. 中国建筑工业出版社.2011.
[5] 国家标准《建筑给水排水及采暖工程施工质量验收规范》GB50242一2002. 北京.中国建筑工业出版社.2002.
[6] 《全国民用建筑工程设计技术措施一给水排水》2009年版.中国计划出版社.2009.
[7] 《建筑给水排水设计手册》第二版.北京.中国建筑工业出版社.2008.
关键词:建筑给排水;水表设置;设计方案
Abstract: along with the development of the national economy more and better, the living standard of people also will improve, for residential construction requirements naturally more and more is also high. All kinds of residential building with a rash also make the building water supply and drainage technology has been developed rapidly. However, with the increase of water supply and drainage engineering, there arise some problems that should be paid attention to, if treatment is not good, will give the user to bring a lot of unnecessary trouble. Water supply and drainage engineering on the realization of the whole function of residential buildings have very important significance. If residential building water supply and drainage engineering problems in, so will directly influence the living feelings of the residents. This paper made a series of discussion.
Key Words: building water supply and drainage; the water meter set; design scheme
中圖分类号:S276文献标识码:A 文章编号:
为了满足住户舒适、美观的要求,在设计工作中要综合考虑各方面的因素,完善施工技术,为住户营造一个美观实用的居住环境。
1、住户给水进户管径的确定
很多住户供水管道距离比较长,为了避免供水管道中产生噪音以及供水点水流不足等情况发生,一定要根据室内的实际情况来选择合适的供水管理直径,并控制好供水压力,从而确保用户用水的方便。一般来说,住宅用户的主要的用水点大多都是集中在厨房和卫生间,一厨一卫可以选择DN25(DN20)的管道,一厨多卫需用DN32(DN25)的管道,以满足使用要求。
2、适当增设单体建筑户外控制阀门
以往的住宅给水设计中,几个楼群共同使用一个总的控制阀门,而每户入户的管道设置一个阀门,这是十分必要的,一旦用户室内供水出现问题,可以及时的关闭阀门,从而防止问题进一步的扩大化。而在整个住宅小区的范围之内应该适当的增加阀门的数量,这样出现供水问题的时候能够及时切断供水,方便进行维修。这样可以减少阀门关闭时对于其它用户用水带来的干扰。笔者认为以停水范围不超过100户时设室外总控制阀为好。
3、注意室外阀门的安装型式
室外安装的阀门大部分都是口径为DN75以上的闸阀,问题是这些装于地下的阀门一旦损坏时如何更换。埋于地下的管道没有多少伸缩的余地,更换阀门时很难塞进法兰垫片,常常要挖地坑和割管子,费时费力,停水时间长。设计时仅需在每一个连接阀的管道处设一个伸缩器则可以较好地解决这一问题。这一点,教科书和规范上都没作规定,却十分实用,且投资不多。
4、地漏与存水弯的配合
凡是室内承接有粪便污水的排水系统的地漏,均应配套存水弯,此可有效地防止串味现象。
5、室内排水管最小管径
一般来讲,污水池、小便器等器具的排出管最小管径为 De50,而含有粪便污水的最小管径为 De110。通过观察后认为这种规定只适用于楼面排水,而不适用于地面排水。原因如下:De50 的管径较小,容易堵塞,且不易疏通。在楼面上排水管系统尚有楼面下管道清扫口可用,而在地面上的小排水管堵塞时,则往往要扒开地面方能维修。笔者的经验是,在地面以下敷设的排水管最小管径宜为DN75,那样并不需要多增加多少投资,也不占用使用空间,但却方便使用和维修。对于楼房粪便污水的底层排出横管,使用 De160 为最小管径更适合中国国情。一般这段横管长度不大,由 De110 改为De160 也不会增加很多投资,但却能极大地减少管道的堵塞机会。而改变管径位置宜设在立管地面以下的地方,这样并不影响地面以上的空间。
6、水表的设置
水表是建筑给排水工程中的一个重要的组成部分,是对用户用水量进行核算的重要的依据,同时能够减少水资源的浪费。传统的水表都是安装在用户的家中,这就使得每次查表都要进入用户家中,给用户的生活带来不便,也使住宅私密性及安全性得不到很好保障,同时也增加了查表人员的工作难度和工作量。针对这种情况,现在一般都把水表设置在用户室外,从而方便进行管理。
6.1 水表集中设置在首层
多层住宅,可将用户的水表安装在建筑的首层的水表箱之内,将供水管道安装在楼梯间内。对于南方地区的一些住宅由于冬天气温较高即使水管直接设置在室外也不用担心被冻裂,可以直接将水表设置在首层的室外,沿着外墙进行用户供水支管的铺设。并宜在进户处设阀门,以便户内管道或龙头损坏漏水能及时关闭。
6.2 水表分别集中设置
在高层建中,水表一般分别集中设置在每层水管井内。但要考虑观察方便。
6.3 分户远传水表的设置
与水表出户不同,分户远传水表是安装在用户室内的,可以设置在卫生间之内等尽量靠近用水点的地。这种水表虽然安装在室内,但是由于其采用先进的科技可以直接实现与该住宅小区的水表管理系统相连,由远程的计算机直接记录水表的读书,不需要进户进行人工抄表极大的减少了工作人员的劳动量,同时提高了抄表的效率,能够及时的收缴水费。缺点是造价高,在物业管理完善的中高档商品房住宅小区可采用远传水表,它是今后水表应用发展的方向。
除了可以使用远传水表之外,一些新兴的住宅小区还可以采用 IC 卡水表,用户可以实现预付费购买一定量的水,然后才可以使用,这样可以有效的减少用户拖欠水费的行为,同时也方便收费。这两种水表都是高科技在供水中的应用,极大的改变了传统意义上的水表管理。
随着人们生活水平的不断提高,这两种水表将会有更加广阔的发展空间。
7 、排水横管的敷设
《住宅设计规范》早就要求;污废水排水横管宜设置在本层套内。这样排水横管渗透时可避免污水进入邻户,管道维修时也不会影响到邻户的正常生活。即使管道有安装和使用问题,也可以很轻易地在本层户内解决。据此产生了同层排水系统。同层排水系统主要有二种不同的方式:一是降板:即采用卫生间楼板(或局部楼板)下层的方式;二是墙排(以管道隐弊安装系统为主要特征)方式。墙排因卫生器具的选择余地较小,地漏难以设置等原因,适用范围较小,在此不展开。
7.1 降板同层排水
降板同层排水是将卫生间结构楼板下沉(局部)200~350mm作为管道敷设空间,污水横管设于下沉室内。这种方式对排水管道的施工较为方便。在使用过程中,经常发生下层住户靠卫生间楼板及侧墙发生渗漏现象。产生渗漏的主要原因有:卫生间地面防水处理不好,地面水渗透到下沉室;部分排水管道漏水进入下沉室,这是降板同层排水最大的缺点----回填层内可能积水。针对以上原因目前采取的措施有:严格做好卫生间地面的防水处理及下沉室四周的防水处理;下沉室内所有排水管道应经严格试压住水试验后方可回填。并在下沉室侧面设置侧排地漏(排水器),以排除可能出现的积水。可地漏(排水器)现行的做法都是接在排水管上,这样有可能排水管的臭气会进入回填层,解决办法是:地漏(排水器)等单独設立管排,且底部间接排放。8、总结
建筑给排水系统与我们的日常生活息息相关,一些设计施工中的细节处理不细致,常常给住户带来诸多问题,设计人员,应本着安全、美观、实用、经济的原则,在实践中努力创新,将问题消除于萌芽状态。
参考文献
[1]宋百盛.浅议建筑给排水系统施工中的若干通病[J]广东科技,2006(5).
[2]张如心.住宅工程水暖系统质量通病及防治[J]山西建筑,2004(24).
[3]陈永科.建筑给排水施工中的问题探讨[J]建材技术与应用,2009(2).
[3]《国家标准建筑给水排水设计规范》GB50015-2003. 2009年版北京.中国计划出版社.2010.
[4] 《国家标准住宅设计规范》GB50096-2011.北京. 中国建筑工业出版社.2011.
[5] 国家标准《建筑给水排水及采暖工程施工质量验收规范》GB50242一2002. 北京.中国建筑工业出版社.2002.
[6] 《全国民用建筑工程设计技术措施一给水排水》2009年版.中国计划出版社.2009.
[7] 《建筑给水排水设计手册》第二版.北京.中国建筑工业出版社.2008.