标准电容器或电容箱的精确测量,目前一般是采用1615、CO-11、QS-16型变压器电容电桥。当被测对象为带外露端钮的三端标准电容器或电容箱时,为了消除端钮间和引线露出部分间的杂散电容影响,必须作两次测量以求得增量电容,即我们通常所说的“增量法”。由于增量电容是两次读数之差,所以检测效率低,同时容易造成计算的疏忽误差。为此我们设计了一种新型的变压器电容电桥一直读高精密电容电桥。
Accurate measurement of standard capacitor or capacitor box, the current is generally used 1615, CO-11, QS-16-type transformer capacitor bridge. When the object to be tested is a three-terminal standard capacitor or capacitor box with exposed terminals, in order to eliminate the influence of stray capacitance between the terminal pins and the exposed part of the lead, two measurements must be made in order to obtain incremental capacitance, that is, The “incremental method.” As the incremental capacitance is the difference between two readings, so the detection efficiency is low, at the same time easily lead to negligence error calculation. To this end, we have designed a new type of transformer capacitor bridge has been reading high-precision capacitor bridge.