医院中子照射器及其辅助系统于2010年年初完成热调试试验,随后投入试运行至今,共开堆99次(天),累积释放能量1 832.42 kW.h(折合积分中子注量为2.198 9×1017cm-2)。试运行期间实验数据显示,医院中子照射器及其辅助系统满足规定的运行限值和条件,未发生任何事故,具有很好的安全性与可靠性,达到了设计要求。
The neutron irradiator and its auxiliary system of the hospital completed the thermal commissioning test in early 2010, and then put into trial operation so far, a total of 99 times (days) were hedged and the cumulative released energy was 1832.42 kW.h (equivalent integral neutron fluence was 2.198 9 × 10 17 cm -2). Experimental data during the trial run shows that the hospital neutron irradiator and its auxiliary system meet the specified operating limits and conditions without any accidents, have good safety and reliability, and meet the design requirements.