论文部分内容阅读
针对船用固定式CO_2灭火系统中控制装置的联锁设计与应用进行探讨,分析了控制装置的开启顺序对灭火系统的影响,介绍了联锁设计原理、控制装置的硬件联锁设计及具体结构,以期最大程度地减少人员操作失误的概率,进一步降低灭火系统失效的潜在风险。
Aiming at the interlocking design and application of control devices in marine stationary CO2 fire extinguishing system, the influence of the opening sequence of control devices on the fire extinguishing system is analyzed. The principle of interlocking design, the hardware interlocking design and the concrete structure of the control device are introduced. With a view to minimizing the probability of human error and further reducing the potential risk of fire extinguishing system failure.