目的通过对营口市某公司聚酯薄膜项目应用的料位计进行职业病危害控制效果(放射防护)评价,了解料位计使用中的辐射水平与防护现状。方法依据国家相关标准,调查和分析料位计使用过程中存在的放射性危害因素、放射防护设施、放射管理制度等内容,并对放射性工作场所辐射水平进行现场的检测,检测项目为X/γ射线周围剂量当量率。结果料位计周围5 cm处剂量率范围为0.24~0.91μSv/h,料位计周围1 m处剂量率范围为0.23~0.62μSv/h,符合国家标准要求;从事料位计巡检维护的6名放射工作人员的适任性评价均为可从事放射工作;该项目电仪部工作人员年有效剂量估算值约为0.02 m Sv,年有效剂量低于本项目建议的管理目标值;建设单位委托有资质的机构进行个人剂量监测。结论该公司料位计的放射防护措施、放射监测结果等均符合相关法律、法规的规定和标准的要求,正常生产后建设项目的职业病防治效果可达到预期控制水平,能够满足预防和控制职业病危害的需要,合理可行,职业病防护设施已达到竣工验收的条件。
Objective To evaluate the effect of occupational disease control (radiation protection) on the level meter used in the polyester film project of a company in Yingkou and understand the radiation level and protection status of the level meter in use. Methods Based on the relevant national standards, the radioactive hazard factors, radiological protection facilities and radiation management systems used in the level meter were investigated and analyzed. The radiation level in the radioactive workplace was detected on site, and the test items were X / γ ray Around the dose equivalent rate. Results The dose rate range of 5 cm around the material level gauge was 0.24-0.91μSv / h. The dose rate range of 1 m around the material level gauge was 0.23-0.62μSv / h, which met the requirements of national standards. The evaluation of the adequacy of the six radiation workers is for radiological work. The estimated effective annual dose of electro-optical instruments for this project is about 0.02 m Sv, and the annual effective dose is lower than the management target recommended by the project. The construction unit Commissioned a qualified agency for personal dose monitoring. Conclusion The radiation protection measures and radiation monitoring results of the company’s level gauges comply with the requirements of relevant laws and regulations and standards. The prevention and control of occupational diseases in construction projects after normal production can achieve the expected level of control and can meet the needs of prevention and control of occupational hazards Needs, reasonable and feasible, occupational disease prevention facilities have reached the conditions for completion and acceptance.