论文部分内容阅读
通过调查研究、试验研究、技术经济对比,分析国产引进型 300 MW机组旁路系统的实际功能和无旁路系统启 动的可行性,以及旁路系统的优化设计。提出进一步改善机组启动性能的措施,对该型机组旁路系统的设置提出 具体建议。
Through the investigation, experimental research, technical and economic comparison, the paper analyzes the actual function of bypass system of domestic imported 300 MW unit and the feasibility of starting without bypass system, as well as the optimization design of bypass system. Put forward measures to further improve the starting performance of the unit and put forward specific suggestions on the setting of this unit’s bypass system.