论文部分内容阅读
针对恒温恒湿空调系统的负荷特性,各空气处理过程的特点,本文结合北京地区的实际工程案例,通过理论计算对能耗进行详细的比较,研究分析了恒温恒湿全直流式空调系统在不同季节的运行特点和节能潜力,提出了系统在满足湿负荷的要求下,可通过设置热泵再热型空调机组,降低系统能耗,实现节能效益。
According to the load characteristics of air temperature and humidity control system and the characteristics of each air treatment process, this paper compares the energy consumption by theoretical calculation with the practical engineering cases in Beijing, and analyzes and analyzes the characteristics of the constant temperature and humidity all-DC air conditioning system in different Seasonal operation characteristics and energy saving potential, the system is proposed to meet the requirements of wet load, heat pump reheat-type air conditioning units can be set to reduce system energy consumption and achieve energy-saving benefits.