【摘 要】
:
The effects of temperature on a surface plasmon resonance (SPR) sensor in Kretschmann configuration are studied experimentally and theoretically. SPR experiments are carried out over a temperature range of 278-313 K in steps of 5 K. A detailed theoretical
【机 构】
:
DepartmentofPhysics,UniversityofScienceandTechnologyofChina,Hefei230026,China2AnhuiKeyLaboratoryofOp
【出 处】
:
ChineseOpticsLetters
论文部分内容阅读
The effects of temperature on a surface plasmon resonance (SPR) sensor in Kretschmann configuration are studied experimentally and theoretically. SPR experiments are carried out over a temperature range of 278-313 K in steps of 5 K. A detailed theoretical model is provided to analyze the variation of performance with varying temperature of the sensing environment. The temperature dependence of the properties of the metal, dielectric, and analyte are studied, respectively. The numerical results indicate that the predictions of the theoretical model are well consistent with the experiment data.
其他文献
虽然激光作用在可见光谱区内外都已经实现,但是高功率输出仅仅在几个波长上产。弥补这一弱点是一件很重要的工作。
只有一个成像透镜的激光三角测量系统不适于测量沟槽轮廓。因为系统的投影光轴与成像光轴成一定角度,沟槽的陡峭边沿会遮挡物体表面照明点的漫反射光进入成像透镜,形成测量死角。为解决这个问题,在满足Scheimpflug条件的激光三角测量法基础上,开发了测量沟槽轮廓的激光双三角测量系统;讨论了像斑探测器积分时间的自动调节、像斑强度分布数据的数字滤波、像斑中心位置的提取和成像光束被凹槽边缘遮蔽的像斑的判别等问题;通过标定实验,确定了双三角测量映射关系。对轮胎胎面轮廓的静态受压变形测量实验表明本系统测量沟槽轮廓的有效性
本文提出和实验论证了两种用简并的四波混频补偿激光放大器相位畸变的方案.在第一种方案中,混频介质饱和吸收体BDN染料二氯乙烷液体置于激光振荡器腔外,用偏振隔离技术,相位补偿的激光辐射从Nd:YAG激光振荡放大系统中耦合出来.实验得到了放大约四倍的后向波输出.在第二种方案中,相位共轭镜置于激光振荡器腔内,BDN染料溶液既作为简并的四波混频介质,又作为调Q介质,获得了补偿放大器相位畸变的调Q激光输出、研究了相位补偿特性.测量了激光输出与染料溶液浓度的关系.
We propose a reflection-type infrared biosensor by exploiting localized surface plasmons in graphene ribbon arrays. By enhancing the coupling between the incident light and the resonant system, an asymmetric Fabry–Perot cavity formed by the ribbons and re
用1.06μm微微秒激光脉冲序列按一定角度激励LiIO3晶体,在4896~6119(?)可见光区内获得8种波长相干喇曼混频辐射,这个复杂受激喇曼散射过程可解释为:在满足位相匹配的条件下,1.06μm强光束一方面与其散射光按非共线型产生二次谐波;另一方面又在晶体形成激元的相干激发,后者对倍频光散射而得到一阶以及高阶的斯托克斯辐射和反斯托克斯辐射,这是二阶与三阶非线性光学过程的综合效应.此外,我们观察到反向的受激散射,其光谱成分与正向的成分不同.并证明,与普通的后向散射也不同,它是1.06μm入射光在晶体出射
激光衍射对刀是通过检测激光衍射条纹峰值点间距来进行对刀间隙测量的方法。但是检测装置中装夹误差的存在会使得入射激光相对于成像光轴呈现斜入射状态, 进而对对刀间隙检查结果及对刀精度产生影响。为了研究斜入射角度对衍射对刀精度的影响规律, 建立了激光斜入射的衍射光强计算模型和峰值点间距误差的计算模型, 进而给出了激光斜入射角度计算模型; 理论结合实验分别提出了通过检测中央衍射条纹光强峰值点位置和两个一级衍射条纹峰值点间距综合进行激光斜入射角度校正的方法; 根据具体实验工艺条件, 确定了入射激光的最佳倾斜角度工艺调
注射微整形手术中可能会出现经皮针头扎破面部动脉血管的情况,这会导致注射药物(如玻尿酸)渗入血管形成栓子、引发血管栓塞,从而致使局部组织缺血、失明甚至中风。为解决这一问题,提出利用光声显微成像引导注射微整形手术。利用带有导针器的光声显微成像探头对固定角度插入的注射针头进行成像,得到针头的行进路线,然后对目标区域进行三维血管成像,通过图像融合并提取其中针头与血管相交区域的像素点数量,可判断针头是否会扎破面部动脉血管,降低手术风险。通过叶脉和活体小鼠成像实验验证了该方法的可行性,结果表明,该方法可以精确地引导扎
分析了三能级Λ原子系统内三色操控引起的色散转换、Kerr非线性增强效应及三色操控对布居反转的影响。分析表明,三色调控下多个双光子通道之间的干涉将引起多个透明窗口内的Kerr非线性增强和布居反转频带增宽。而三色场内两边频场的相对相位之和对色散变换、布居反转和Kerr非线性增强效应也起着至关重要的影响。相位之和从0调为π,将引起多个频带内色散正负转换,从而使得慢光速向超光速转换,引起Kerr非线性增强对应的频带位置改变,并引起布居反转对应的频带进一步增宽。相位之和影响以上非线性效应的原因也得到了分析。