论文部分内容阅读
用3种指示剂监测医院压力蒸汽灭菌的合格率,结果互有差异,以嗜热脂肪杆菌芽胞菌片指示的合格率最高。其中,以铝饭盒盛装的物品合格率最低,布包物品最高,但均未全部达到灭菌。对76所医院消毒液调查,总菌数超过250个/ml的样本达13.59%;消毒液的污染率随使用时间延长而增加,使用3天内的污染率仅6.71%,7天以上则达26.82%。
Three kinds of indicators were used to monitor the hospital steam pressure sterilization rate, the results are different from each other to Bacillus stearothermophilus cerebrospome indicates the highest pass rate. Among them, the aluminum boxes containing the lowest rate of qualified items, the highest items of cloth, but not all achieved sterilization. In the 76 hospital disinfectant survey, the samples with the total number of bacteria exceeding 250 / ml amounted to 13.59%. The contamination rate of disinfectant increased with the prolongation of usage time. The pollution rate within 3 days was only 6.71%, while it was 26.82 after 7 days %.