Heat Transfer Analysis for Dropwise-Filmwise Hybrid Surface of Steam on Vertical Plate

来源 :热科学学报(英文版) | 被引量 : 0次 | 上传用户:dfhjaljgjre
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
A model is proposed to predict and evaluate the heat transfer characteristics of dropwise-filmwise hybrid surface.This is approached by modifying the original drop-size distribution,which is defined for fully dropwise condensation (DWC) and making it applicable for dropwise-filmwise condensation (DFC).The modification is achieved by simulation work to determine two parameters: the area fraction occupied by large drops f and the ratio of the maximum radius of newly formed drops to that of larger drops γ.Simulation results show a good agreement with the literature for fully DWC and provide a correlation for each parameter with respect to DWC region width in the DFC hybrid surface.The present model evaluates the heat transfer performance of DFC by utilizing these correlations.A comparison is made between the proposed model with experimental work from the literature and results show a good agreement.While changing filmwise condensation (FWC) region width significantly affects the overall heat transfer performance,utilizing smaller width to that of DWC region has the advantage over fully DWC.Furthermore,surface renewal within the hydrophobic region is controlled by adjusting the DWC region width.When the ratio of drop maximum diameter to DWC region width is unity,surface renewal is achieved by drops merging to adjacent FWC regions only.When the ratio is less than unity,surface renewal is achieved by sweeping of departing drops within the hydrophobic region and by merging.For each case,an optimum DWC region width which corresponds to the maximum DFC heat flux is defined.
其他文献
The tip leakage flow in different axial gaps is numerically investigated based on the Reynolds-Averaged Navier-Stokes equations and k-ω SST turbulent model usi
The non-linear temperature glide in the supercritical CO2 cooling process makes the heat transfer pinch point of heat exchanger show multiplicity,like size,loca
The stationary lumped-cell model was developed and used to simulate the thermal characteristics of domestic biomass boiler with helically coiled tube heat excha
Molten salt and supercritical carbon dioxide (S-CO2) are important high temperature heat transfer media,but molten salt/S-CO2 heat exchanger has been seldom rep
The effects of the flame temperature and the absorption coefficient on interactions between radiative heat transfer and the flame behavior were numerically inve