论文部分内容阅读
当发现克虏伯破碎锤打击力和工作频率降低时,首先应检查其蓄能器的压力。如果蓄能器内的压力值在厂家规定的最小压力值以上时,则不必进行充气。检查压力时,锤体保持正常工作温度60-70℃,且平放,不让锤尖承受外力。如果蓄能器内的压力值低于厂家规模的最小压力值,则需要检查蓄能器内的膜片。如果蓄能器内的膜片有破损,则必须更换膜片,再对蓄能器充气;如果膜片完好,则可直接充气(所有充气的工具及附件都在其专用工具箱内)。充气时,将气压溢流阀与氮气瓶
When it is found that the Krupp hammer disrupts and the operating frequency decreases, first check the pressure of its accumulator. It is not necessary to inflate if the pressure in the accumulator is above the minimum pressure specified by the manufacturer. Check the pressure, the hammer body to maintain normal operating temperature 60-70 ℃, and flat, do not let the hammer tip to withstand external forces. If the pressure in the accumulator is lower than the minimum pressure at the manufacturer’s scale, check the diaphragm in the accumulator. If the diaphragm inside the accumulator is damaged, the diaphragm must be replaced before the accumulator is inflated. If the diaphragm is intact, it can be inflated directly (all inflated tools and accessories are in their special toolbox). When inflation, the pressure relief valve and nitrogen bottle