论文部分内容阅读
Based on the fact that the house dust usually falls on the ground,the floor level slit exhaust ventilation system including inlet located at the ceiling and outlet of slit exhaust installed at cer between wall and floor was considered.Experiments and simulations were performed to investigate the flow and diffusion fields that are affected by this floor level slit exhaust ventilation system.The characteristics of airflow with experiments and computation fluid dynamics(CFD)are generally similar except airflow at the location of impinging flow and the location right below the inlet.Riboflavin particles were used as the house dust.For the spatial distribution of riboflavin particles in the ventilation system before operation,due to the influence of gravity,different sizes of particles show smooth decay curve.After floor level slit exhaust ventilation system is operated,the decay rate of the particles becomes faster than that after the ventilation system is powered on,and the particles with diameter of 0.5-3.0 μm in the experimental data and calculated values show good agreement.