论文部分内容阅读
电爆网路的最大特点是在敷设后可进行网路故障检测。检测法基本上有两种,一种是传统的电阻法,另一种是新型的电流法。 (一)电阻法检测电爆网路故障 电阻法检测电爆网路故障,是依靠现有的爆破电表(B—1型爆破电表)或电雷管测试仪(205电桥)等。它们是通过检测电爆网路的电阻,检查整个网路及支路的通断情况。随着爆破技术和爆破规模的发展与扩大,所用电雷管的数量逐渐增多,爆破网路也越来越复杂。特别是整个网路联好以后,
Electrical explosion network is the biggest characteristic of network failure detection after laying. There are basically two detection methods, one is the traditional resistance method, the other is a new type of current method. (A) resistance method to detect electric burst Network fault resistance method to detect electric burst network failure is to rely on the existing blasting meter (B-1 blasting meter) or electric detonator tester (205 bridge) and so on. They are by detecting the electric burst network resistance, check the entire network and branch off-line situation. With the development and expansion of blasting technology and blasting scale, the number of electric detonators used is gradually increasing, and the blasting networks are becoming more and more complicated. Especially after the entire network together,