制备了聚缬氨酸修饰电极,考察氧氟沙星在此电极上的电化学行为,并测定其含量。在-1.4~2.5 V电位范围内,以100 mV/s扫描速率循环扫描10周,制备的修饰电极可使氧氟沙星的电化学信号最强。在pH 6.0的枸橼酸-磷酸氢二钠缓冲液中,扫描速率80 mV/s,氧氟沙星在1.00×10-7~5.65×10-5 mol/L浓度范围内线性关系良好,最低检测限为8.50×10-8 mol/L。低、中、高浓度样品回收率分别为95.0%、98.3%和102.1%,RSD分别为2.97%、4.33%和2.68%。
Poly-valine modified electrode was prepared to study the electrochemical behavior of ofloxacin on the electrode and determine its content. In the potential range of -1.4 ~ 2.5 V, scanning cycles of 100 mV / s were performed for 10 weeks. The prepared modified electrode could make the electrochemical signal of ofloxacin the strongest. In pH 6.0 citric acid-disodium hydrogen phosphate buffer, the scan rate was 80 mV / s and ofloxacin was linear in the concentration range of 1.00 × 10-7 ~ 5.65 × 10-5 mol / L with the lowest The detection limit is 8.50 × 10-8 mol / L. The recoveries of low, medium and high concentration samples were 95.0%, 98.3% and 102.1%, respectively, with RSDs of 2.97%, 4.33% and 2.68%, respectively.