我市某单位1台载货电梯,在维修过程中,1名维修人员被剪切头部当场死亡。该电梯为额定载重量2t、额定速度0.5m/s、3层3站、水平滑动中分门交流双速电梯。事故发生时,有3名维修人员在现场操作。1名在机房。1名在轿厢内,1名在1层层门外,层门外的维修人员被层门剪切死亡。经检查死者面对层门、右手抓住开启的右扇门边。层门中间开启为120mm的门缝,双膝跪地,头部有明显的伤痕。
A unit of our city a cargo elevator, in the maintenance process, a maintenance staff was cut his head on the spot death. The elevator rated load 2t, rated speed of 0.5m / s, 3 3-story, horizontal sliding in the sub-two-door AC two-speed elevator. At the time of the accident, three maintenance personnel were operating at the scene. 1 in the engine room. One in the car, one in a layer outside the door, the layer of maintenance personnel outside the door layer cut death. After checking the dead facing the landing door, the right hand to seize the right side of the open door. The middle of the door opened for the 120mm door seam, knees, obvious head injuries.