论文部分内容阅读
一、人体红外温度计校准装置人体红外温度计校准装置采用液体恒温的方式,液体恒温具有均匀性好、易控制、波动小等特点。根据红外体温计的常用温度,在设计中笔者选用水作为恒温介质。该装置如图1所示,由搅拌机构、黑体腔、标准铂电阻温度计、恒温槽体、温控系统组成,其中黑体腔采用了可更换结构,配备了适用于红外耳温计的10mm开口黑体腔、适用于红外额温计的17mm开口黑体腔,适用于玻璃体温计的孔板结构,可用于常见的
First, the human infrared thermometer calibration device Human infrared thermometer calibration device using liquid thermostat way, the liquid temperature uniformity, easy to control, small fluctuations and so on. According to the common temperature of the infrared thermometer, the author selects water as the constant temperature medium in the design. The device shown in Figure 1, by the stirring mechanism, black body cavity, the standard platinum resistance thermometer, constant temperature tank, temperature control system, which uses a black body cavity changeable structure, equipped with infrared ear thermometer 10mm open black body Cavity, 17mm open black body cavity for infrared thermometers, suitable for glass plate thermometer orifice structure, can be used for common