Comparison of the clinical accuracy of cervical (C2-C7) pedicle screw insertion assisted by fluorosc

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:lizhiguo518
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background The complicated anatomy of the cervical spine and the variation among pedicles reduces the accuracy and increases the risk of neurovascular complications associated with screw implantation in this region. In this study, we compared the accuracy of cervical (C2-C7) pedicle screw fixation assisted by X-ray fluoroscopy, computed tomography (CT)-based navigation, or intraoperative three-dimensional (3D) C-arm navigation.Methods This prospective cohort study was performed in 82 consecutive patients who underwent cervical pedicle screw fixation. The accuracy of screw insertion was assessed by postoperative CT scan with 3D reconstruction. The accuracy of screw insertion was assessed as: excellent (screw completely within pedicle); acceptable (≤ 1 mm screw outside pedicle cortex); poor (>1 mm screw outside pedicle cortex).Results A total of 145 screws were inserted in 24 patients who underwent C-arm fluoroscopy. Of these, 96 screws (66.2%) were excellent, 37 (25.5%) were acceptable, and 12 (8.3%) were poor. One hundred and fifty-nine screws were inserted in 29 patients in the CT-based navigation group. Among these, 141 (88.7%) were excellent, 14 (8.8%) were acceptable, and 4 (2.5%) were poor. A total of 140 screws were inserted in 29 patients in the intraoperative 3D C-arm navigation group, of which 127 (90.7%) were excellent, and 13 (9.3%) were acceptable. No severe or permanent neurovascular complications associated with screw insertion were observed in any patient.Conclusione CT-based and intraoperative 3D C-arm navigation were similarly accurate, and were both significantly more accurate than C-arm fluoroscopy for guiding cervical pedicle screw fixation. They were able to accurately guide the angle and depth of screw placement using visual 3D images. These two techniques are therefore preferable for high-risk cervical pedicle screw fixation. The ease and convenience of intraoperative 3D C-arm navigation suggests that it may replace virtual-fluoroscopy and CT-based navigation systems in future clinical applications.
其他文献
A new brominated C15-acetogenin,namely,laurenidificin,was isolated from the marine red alga Laurencia nidifica.Its structure was determined on the basis of spec
Background Recurrence of hallux valgus is considered to be the most common problem experienced postoperatively.We designed and caried out operations to correct
AIM: To investigate the effects of blueberry on hepatic fibrosis and NF-E2-related factor 2 ( Nrf2) transcription factor in rats. METHODS: Forty-five male Sprag
Background Airway symptoms in asthma are related to decrease of epinephrine secretion, which may be ascribed to elevated nerve growth factor (NGF) in the organi
The clinical course of Crohn’s disease and ulcerative colitis is highly variable between patients,and this has therapeutic implications.A number of clinical fe
AIM: To assess the treatment and tumor-related variables associated with outcome after treatment of spontaneously ruptured hepatocellular carcinoma (HCC).METHOD
Nonalcoholic fatty liver disease(NAFLD) is a common clinical condition which is associated with metabolic syndrome in 70% of cases.Inappropriate dietary fat int
Pancreatic tumors with combined exocrine and endocrine features are rare. Most reported cases are classi-fied as mixed exocrine and endocrine carcinoma of the p