论文部分内容阅读
对秦山核电厂安全分析报告中有关反应性事故进行了审核计算,这些事故包括:(1)硼稀释事故;(2)燃料组件错装位事故;(3)控制棒弹棒事故;(4)控制棒误动作事故;(5)控制棒组件在功率运到工况下失控抽出事故;(6)控制棒组件在
The Qinshan Nuclear Power Plant safety analysis report on the audit of reactive accidents were calculated, these accidents include: (1) boron dilution accident; (2) the wrong fuel assembly accident; (3) control rod bomb accident; (4) Control rod misoperation accident; (5) control rod assembly out of control in the power to the operating conditions out accident; (6) control rod assembly in