EC2— 2 74型透平膨胀机是天然气深冷处理装置的关键制冷设备。频繁的开机与停机、工艺气带液和润滑油受污染等 ,使膨胀机的动平衡出现故障 ,造成轴承推力面、主轴推力面和密封组件的严重损坏 ,结果机组不得不停止运转。通过故障原因分析和解体检查及维修 ,整个系统和主机的故障最终得到排除。检修后的运行表明 ,各项参数正常 ,检修获得成功。为保障机组安全平稳运行 ,减少或避免某些事故的发生 ,提出了防止固体杂质、水和重烃进入增压机 ,凝液进入润滑油罐和改善材质以保护主轴推力面等多项措施。
EC2- 2 74 Turbocharger is the key refrigeration equipment for natural gas cryogenic treatment plant. Frequent start-up and shut-down, process gas with liquid and lubricating oil pollution, etc., the dynamic balance of the expander failure, resulting in bearing thrust surface, the thrust surface of the spindle and seal components of the serious damage, the result of the unit had to stop running. Through the analysis of the cause of the failure and disassembly inspection and maintenance, the entire system and the host of the fault eventually be ruled out. Maintenance after the operation shows that the parameters of normal, overhaul was successful. In order to ensure the safe and stable operation of generating units and to reduce or avoid the occurrence of some accidents, a number of measures have been put forward to prevent solid impurities, water and heavy hydrocarbons from entering the supercharger, condensate entering the lubricating oil tank and improving the material to protect the thrust surface of the main shaft.