Correction factors of both Rem-meters, the 10 inch diameter single-sphere Remmeter and the standard A-B Rem-meter, were estimated for measuring high energy neutron dose equivalent outside a concrete shielding wall and the effects that the emitted neutron spectra become remarkably “harder” penetrated through a concrete shielding wall, and the energy response of the Rem-meter were taken in account. The estimated results could be applied in the measurement of neutron dose equivalent for the intermediate energy heavy ion reactions to avoid the difficulty induced by the energy response of the Rem-meters.
Correction factors of both Rem-meters, the 10 inch diameter single-sphere Remmeter and the standard AB Rem-meter, were estimated for measuring high energy neutron dose equivalent outside a concrete shielding wall and the effects that the emitted neutron spectra become remarkably “ harder ”penetrated through a concrete shielding wall, and the energy response of the Rem-meter were taken in account. The estimated results could be applied in the measurement of neutron dose equivalent for the intermediate energy heavy ion reactions to avoid the difficulty induced by the energy response of the Rem-meters.