论文部分内容阅读
本文对日本各地纤维结肠镜(下简称纤结镜)检查发生的并发症作了统计和分析。接受检查共54,463例次,包括诊断性检查51,196例次,电灼息肉3,267例次。共发生并发症116例(占0.21%),其中主要有穿孔68例(占0.12%),出血30例(占0.06%),诊断性检查发生并发症81例(占0.16%),其中主要有穿孔59例(占0.12%),出血7例(占0.014%)。电灼息肉发生并发症35例(占1.07%),其中主要有穿孔9例(占0.28%),出血23例(占0.70%).穿孔部位有53例发生在乙状结肠,其次是乙状结肠与降结肠交界处,再其次是降结肠。54例穿孔发生在只做镜检的部位,5例在施行活检的部位,9例在
This article made a statistical analysis of the complications of fibro-colonoscopy (referred to as fibroscopy) in various parts of Japan. A total of 54,463 examinations were performed, including 51,196 cases of diagnostic tests and 3,267 cases of electrocautery polyps. Complications occurred in 116 cases (0.21%), of which 68 cases (0.12%) were perforation, 30 cases (0.06%) were bleeding, and 81 cases (0.16%) were diagnosed as complications, of which there were Perforation in 59 cases (0.12%), bleeding in 7 cases (0.014%). There were 35 cases (1.07%) of the complications of electrocautery polyps, of which 9 cases (0.28%) had perforation, 23 cases (0.70%) had perforation, 53 cases perforated in sigmoid colon, followed by sigmoid and descending colon Junction, followed by descending colon. 54 cases of perforation occurred only in the site of microscopic examination, 5 cases in the biopsy site, 9 cases