Drop test and crash simulation of a civil airplane fuselage section

来源 :Chinese Journal of Aeronautics | 被引量 : 0次 | 上传用户:wosee_2008
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Crashworthiness of a civil airplane fuselage section was studied in this paper. Firstly, the failure criterion of a rivet was studied by test, showing that the ultimate tension and shear failure loads were obviously affected by the loading speed. The relations between the loading speed and the average ultimate shear, tension loads were expressed by two logarithmic functions. Then, a vertical drop test of a civil airplane fuselage section was conducted with an actual impact velocity of6.85 m/s, meanwhile the deformation of cabin frame and the accelerations at typical locations were measured. The finite element model of a main fuselage structure was developed and validated by modal test, and the error between the calculated frequencies and the test ones of the first four modes were less than 5%. Numerical simulation of the drop test was performed by using the LS-DYNA code and the simulation results show a good agreement with that of drop test. Deforming mode of the analysis was the same as the drop test; the maximum average rigid acceleration in test was 8.81 g while the calculated one was 9.17 g, with an error of 4.1%; average maximum test deformation at four points on the front cabin floor was 420 mm, while the calculated one was 406 mm, with an error of 3.2%; the peak value of the calculated acceleration at a typical location was 14.72 g, which is lower than the test result by 5.46%; the calculated rebound velocity result was greater than the test result 17.8% and energy absorption duration was longer than the test result by 5.73%. First, the failure criterion of a rivet was studied by test, showing that the ultimate tension and shear failure loads were obviously affected by the loading speed. The relations between the loading speed and the average ultimate shear, tension loads were expressed by two logarithmic functions. Then, a vertical drop test of a civil airplane fuselage section was conducted with an actual impact velocity of 6.85 m / s, meanwhile the deformation of cabin frame and the accelerations at The finite element model of a main fuselage structure was developed and validated by modal test, and the error between the calculated frequencies and the test ones of the first four modes were less than 5%. Numerical simulation of the drop test was performed by using the LS-DYNA code and the simulation results show a good agreement with that of drop test. Deforming mode of the analysis was the same the maximum average rigid acceleration in test was 8.81 g while the calculated one was 9.17 g, with an error of 4.1%; average maximum test deformation at four points on the front cabin floor was 420 mm, while the calculated one was 406 mm with an error of 3.2%; the peak value of the calculated acceleration at a typical location was 14.72 g, which is lower than the test result by 5.46%; the calculated rebound velocity result was greater than the test result 17.8% and energy absorption duration was longer than the test result by 5.73%.
其他文献
目的探讨腹腔镜胆囊切除术(LE)的适应证、手术操作要点、并发证及临床效果。方法选择近年来本院行腹腔镜胆囊切除术的患者98例,对其临床资料进行回顾性总结分析。结果本组所有病
A new water-cooling Gardon-type heat power measuring apparatus is designed to meet the need of heat power source management and distribution. The steady state m
The real dynamic thrust measurement system usually tends to be nonlinear due to the complex characteristics of the rig, pipes connection, etc. For a real dynami
期刊
为研究纤维金属层板(FML)的非线性变形行为和损伤机制,对GLARE2-2/1、GLARE2-3/2、GLARE3-2/1、GLARE3-3/2、GLARE6-2/1和GLARE6-3/2层板进行了静力拉伸测试,同时采用数字图
2002年10月28日至31日,中国机械工程学会设备维修分会在江苏无锡市召开了第十一届全国设备监测与诊断学术会议,来自全国24个省市16个行业的企业、部队、院校、研究所的诊断
When manned spacecraft comes back to the earth, it relies on the impact attenuation seat to protect astronauts from injuries during landing phase. Hence, the se
A new type of plasma rocket engine, the Kabila rocket, using a radioisotope heated thermionic heating chamber instead of a conventional combustion chamber or ca
Background:Metabolic syndrome (MS) is a risk factor for stroke and thromboembolism event.Left atrial or LA appendage (LA/LAA) thrombus is a surrogate of potenti