论文部分内容阅读
瑞典AK──10血液透析机电导故障分析及调校方法济南军区总医院血液净化中心张永寿,胡斌瑞典AK—10系列血液透析机的标准透析液是通过控制吸入A、B浓缩液的比例,与反渗水混合制成。A、B浓缩液的基本控制原理是:A液由BCM层的瓷泵控制,B液由DFM层的...
Sweden AK ─ 10 hemodialysis electromechanical conduction failure analysis and adjustment methods Jinan Military General Hospital Blood Purification Center Zhang Yongshou, Hu Bin Sweden AK-10 series hemodialysis machine standard dialysate is controlled by inhalation of A, B concentrate ratio , mixed with reverse osmosis water. The basic control principle of A, B concentrate is: A liquid is controlled by the porcelain pump of BCM layer, B liquid is from DFM layer...