论文部分内容阅读
2DSJ—0.016/600塑高压试压泵。工人在试压时,高压水经常打不上去。开始时,有的人认为是阀体3内的高压进出水阀锈死;也有人认为是高压缸2的v型皮碗不密封。故障排除后,停机以后再开机,高压水仍然打不上去。经过认真检查,发现每次停机后,水便从皮管2流入水箱3,水管里的水流光了,便造成水管里蓄满空气。当再次开机时,空气出不来,阀体1内的高压进出水阀就打不开。针对这原因,我们在每次开
2DSJ-0.016 / 600 plastic high-pressure test pump. When workers try to pressure, high pressure water often can not hit. Initially, some people think that the valve body 3 high-pressure water inlet valve rust; some people think that the v-type high pressure cylinder 2 cup is not sealed. After troubleshooting, stop and then boot, high-pressure water still can not beat up. After careful examination, it was found that after each shutdown, the water flowed into the water tank 3 from the skin tube 2, and the water in the water pipe was gone, resulting in the air pipe being full of air. When the boot again, the air can not get out of the body of a high-pressure inlet and outlet valves can not open. For this reason, we open each time