论文部分内容阅读
对随机放置ML375、Fincoid350、TCu220c和镀铜宫腔形IUD(UCDCu)各100例,临床观察3年,随访率99.75%。研究结果表明:4种IUD的妊娠率分别为3.19%、5.28%、2.16%及3.09%,其中Fincoid350最高,TCu220c最低,各组间差异无显著性意义(P>0.05);脱落率为3.14%、6.44%、5.16%及2.07%,其中Fincoid350最高,UCDCu最低,两者间相比无显著性差异(P>0.05);因症取出率分别为4.06%、8.99%、3.07%及1.03%,TCu220c和UCDCu的因症取出率明显低于Fincoid350,皆有显著性意义(P<0.05);粗累积续用率分别为89.00%、79.84%、90.00%及93.94%,UCDCu明显高于Fincoid350,且有极显著性意义(P<0.01)。
100 cases of ML375, Fincoid350, TCu220c and copper-coated uterine cavity IUD (UCDCu) were randomly placed. The clinical observation was 3 years and the follow-up rate was 99.75%. The results showed that the pregnancy rates of the 4 kinds of IUDs were 3.19%, 5.28%, 2.16% and 3.09%, respectively. The highest Fincoid350 and the lowest TCu220c were found among the 4 groups (P> 0.05). The shedding rates were 3.14%, 6.44%, 5.16% and 2.07%, respectively. The highest Fincoid 350 and the lowest UCDCu were found (P> 0.05 ). The removal rates of TCu220c and UCDCu were significantly lower than those of Fincoid350 (4.06%, 8.99%, 3.07% and 1.03%, respectively) (P <0.01). UCDCu was significantly higher than that of Fincoid350 (89.00%, 79.84%, 90.00% and 93.94%, respectively) .