【摘 要】
:
Previous studies have shown cost effectiveness and quality-of-life benefit of pneumatic compression therapy (PCT) for lymphedema (LE). Insurers, such as the Centers for Medicare/Medicaid (CMS), however, desire visual proof that PCT moves lymph. Near-infra
【机 构】
:
CenterforMolecularImaging,TheBrownInstituteforMolecularMedicine,UTHealth,Houston,Texas,USAMegoAfek/L
【出 处】
:
JournalofInnovativeOpticalHealthSciences
论文部分内容阅读
Previous studies have shown cost effectiveness and quality-of-life benefit of pneumatic compression therapy (PCT) for lymphedema (LE). Insurers, such as the Centers for Medicare/Medicaid (CMS), however, desire visual proof that PCT moves lymph. Near-infrared fluorescence lymphatic imaging (NIRFLI) was used to visualize lymphatic anatomy and function in four subjects with primary and cancer treatment-related LE of the lower extremities before, during, and after PCT. Optically transparent and windowed PCT garments allowed visualization of lymph movement during single, 1h PCT treatment sessions. Visualization revealed significant extravascular and lymphatic vascular movement of intradermally injected dye in all subjects. In one subject with sufficient patent lymphatic vessels to allow quantification of lymph pumping velocities and frequencies, these values were significantly increased during and after PCT as compared to pre-treatment values. Lymphatic contractile activity in patent lymphatic vessels occurred in concert with the sequential cycling of PCT. Direct visualization revealed increased lymphatic function, during and after PCT therapy, in all LE-affected extremities. Further studies are warranted to assess the effects of PCT pressure and sequences on lymph uptake and movement.
其他文献
Localized modes in one-dimensional (1D) media with uniaxial scatterers that are assumed to be order in spatial location but disorder in spatial orientation of their optical axis are investigated. Based on the holistic effect model in random laser, i.e., t
由于共焦针孔的加入及现有太赫兹激光器输出不稳定,太赫兹共焦扫描显微成像所得图像的质量不高,将双边滤波算法应用于透射式太赫兹共焦扫描显微成像图像去噪复原,通过研究确定了适合于该情况的双边滤波参数,并且与中值滤波、均值滤波和开运算滤波的滤波性能进行比较,证明了双边滤波算法应用于透射式太赫兹共焦扫描显微成像图像去噪复原的可行性。
为了在任意非平行斜面上重建数字全息像,提出了一种基于角谱旋转变换和插值的数字处理方法,用角谱衍射理论进行了分析,给出了正反旋转两种数字插值方法,基于旋转变换信息量不变的原则分析了倾斜面上的抽样间隔取值范围,其大小取决于斜面带宽和全息图空间带宽积大小。实现了在71°倾斜物面上的全息重建,消除了倾斜造成的局部离焦现象,同时验证了算法在斜面上抽样间隔取值范围。
本文介绍一种用红宝石激光器作光源的快速过程高速摄影装置3这种激光器产生一系列高重复率巨脉冲。这种装置曾用来分析聚焦激光束与金属靶的相互作用。
为保障偏振扫描仪长期在轨的偏振测量精度,研究了偏振扫描仪的星上偏振定标原理与方法。首先,针对分孔径和分振幅的技术特点,结合实际的误差来源,理论推导了系统探测矩阵;其次,根据仪器参数,利用已知偏振态的线偏振光和非偏振光,推导了星上偏振定标方程;然后,设计了用于星上偏振定标的线偏振定标器和非偏振定标器;最后,提出了利用已知偏振度的太阳漫射板辐射定标数据来校正偏振扫描仪的低偏振度测量精度和稳定性。所提出
Equilateral triangle semiconductor microcavities with tensile-strained InGaAsP multi-quantum-well as the active region are fabricated by the inductively coupled plasma (ICP) etching technique. The mode characteristics of the fabricated microcavities are i
苏修结晶学研究所的科学工作者以1.5千瓦的泵浦功率在Y3Al5O12/Nd3 晶体中获得了脉冲激光作用。釆用的晶体中的一些由助熔盐法生长,而另一些则由熔融法生长。高能态(4F3/2)的寿命(在室温和室温以下) 从0.2变化到0.18微秒。
T-rays is sensitive to covalently cross-linked proteins and can be used to probe unique dynamic properties of water surrounding a protein. In this paper, we demonstrate the unique absorption properties of the dynamic hydration shells determined by hemaggl
本文是我们对分布反馈InGaAsP/InP半导体激光器研究的继续。分布反馈激光器必要的结构是波导层中有光学周期非均匀性(衍射光栅)。在文献[1]中研究的分布反馈激光器,其光学周期的非均匀性是由于波导表面上的皱纹引起的。文献[2,3,5]报导了用相干激光淬火形成光学周期非均匀性而获得分布反馈的异质结激光器的研究实验结果。文献[4]演示了制备动态衍射光栅来控制分布反馈的半导体激光器的可能性。