Long-term effects of biodegradable versus durable polymer-coated sirolimus-eluting stents on coronar

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:zhypku
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background The durable presence of polymer coating on drug-eluting stent (DES) surface may be one of the principal reasons for stent thrombosis. The long-term coronary arterial response to biodegradable polymer-coated sirolimus-eluting stent (BSES) in vivo remained unclear.Methods Forty-one patients were enrolled in this study and virtual histology intravascular ultrasound (VH-IVUS) was performed to assess the native artery vascular responses to BSES compared with durable polymer-coated SES (DSES) during long-term follow-up (median: 8 months). The incidence of necrotic core abutting to the lumen was evaluated at follow-up.Results With similar in-stent late luminal loss (0.15 mm (0.06-0.30 mm) vs. 0.19 mm (0.03-0.30 mm), P=0.772), the overall incidence of necrotic core abutting to the lumen was significantly less in BSES group than in DSES group (44% vs.63%, P <0.05) (proximal 18%, stented site 14% and distal 12% in BSES group, proximal 19%, stented site 28% and distal 16% in DSES group). The DSES-treated segments had a significant higher incidence of necrotic core abutting to the lumen through the stent struts (73% vs. 36%, P <0.01). In addition, more multiple necrotic core abutting to the lumen was observed in DSES group (overall: 63% vs. 36%, P <0.05). Furthermore, when the stented segments with necrotic core abutting to the lumen had been taken into account only, DSES-treated lesions tended to contain more multiple necrotic core abutting to the lumen through the stent struts than BSES-treated lesions (74% vs. 33%), although there was no statistically significant difference between them (P=0.06).Conclusions By VH-IVUS analysis at follow-up, a greater frequency of stable lesion morphometry was shown in lesions treated with BSESs compared with lesions treated with DSESs. The major reason was BSES produced less toxicity to the arterial wall and facilitated neointimal healing as a result of polymer coating on DES surface biodegraded as time went by.
其他文献
Background The role of plasma high sensitivity C-reactive protein (hs-CRP) in in-stent restenosis (ISR) remains controversial. We investigated plasma hs-CRP lev
针对一台吸收塔全面检验中发现的严重缺陷--冷裂纹,分三个方面分析讨论了缺陷产生的原因和避免或预防缺陷的措施,旨在通过交流,提高压力容器焊接的质量,同时增强我们发现缺陷
目的探讨神经肌电图在诊断运动神经元病中的作用。方法选测3个以上有或无病理改变的肢体的肌电图及神经电图。结果大多数肌肉出现插入电位延长和/或出现少量~大量(+~+++)纤颤、
Background Primary percutaneous coronary intervention (PCI) has been clearly identified as the first therapeutic option for patients with acute ST-segment eleva
Background Off-label application of drug-eluting stents (DES) during percutaneous coronary intervention (PCI) was not uncommon in daily practice, however DES in
Background Available drug-eluting stents (DES) have achieved great success in reducing restenosis rates. Recently,investigators have demonstrated that the durab
目的探讨妊娠合并血小板减少的原因及治疗方法。方法对54例妊娠合并血小板减少患者的临床资料进行回顾性分析。结果妊娠合并血小板减少的主要原因是特发性血小板减少性紫癜(I