《建筑工人》2000年第10期郁华云《现浇楼板板角裂缝的成因分析及预防》的文章,通过调查和分析找出了该种裂缝的原因,并提出预防措施,在工程上具有一定的实用价值,但略感不足,愿补充以下一些看法。一、该种裂缝具有普遍性1.首先我认为该文所说的裂缝不仅在南方、在汕头市有,而且在北方、在大连开发区也存在类似情况。例如大连开发区金源北里就多次出现过这种裂缝,尤其是外角的大房间,这种类型的斜裂缝可以多达3条,分布
Yu Hua-yun, “Forming Analysis and Prevention of Corner Cracks in Cast-in-situ Floor Slab”, Through investigating and analyzing the causes of this type of cracks and proposing preventive measures, it has a certain Practical value, but a little less, would like to add some of the following comments. First, the kind of cracks is universal 1. First of all, I think the cracks mentioned in this article are not only in the south but also in Shantou. In the north, similar situations exist in the development zone in Dalian. For example, Dalian Development Zone Jinyuan Beili where there have been many such cracks, especially in the outer corner of the room, this type of oblique cracks can be up to 3, the distribution