论文部分内容阅读
在2008—2009年为期1年的广州某高校自然通风建筑现场调研的基础上,对23周共计921人次的调研数据在热环境、人体热反应及适应行为等方面进行了分析,得到了我国湿热地区典型自然通风建筑的室内热环境全年变化特征,获取了热感觉与标准有效温度的确定关系,验证了修正的PMV模型的适用性,分析得到我国湿热地区自然通风建筑的期望因子为0.8,同时获得了调整服装、开窗与使用风扇等适应行为的变化规律。
On the basis of a one-year field study of natural ventilation buildings in a university in Guangzhou during 2008-2009, a total of 921 survey data in 23 weeks were analyzed in the aspects of thermal environment, human thermal response and adaptive behavior, and the results showed that China’s hot and humid Regional typical natural ventilation indoor thermal environment throughout the year changes in the characteristics obtained thermal sensation and the standard effective temperature to determine the relationship between validated the modified PMV model applicability analysis of the natural ventilation in our hot and humid areas expected factor of 0.8, At the same time, we got the change rules of adapting behaviors such as adjusting clothing, opening the window and using the fan.