论文部分内容阅读
几年来,每到夏秋季节,室温较高,我院常有个别病人发生输液热原反应(下简称反应)。为找出原因,我们用家兔法对自制输液每批都按药典法做了检查,当病人发生反应时,针对同批号输液(包括外地药厂出品的输液)和输液器具做了热原追查,现将结果介绍于下。输液的热原检查1.从1970~1978年自制各种输液共检查245批,其中有一批热原阳性,其余全部阴性。2.病人发生反应时,立即对库存的同批号输液做了复查,共检查20批均未检出热原,个别还行健康
In recent years, every summer and fall season, room temperature is high, our hospital often have individual patients with infusion of pyrogen reaction (hereinafter referred to as reaction). To find out the reasons, we use the rabbit method for each batch of homemade infusion according to the Pharmacopoeia Law to do a check, when the patient reaction, for the same batch of infusion (including the field of pharmaceutical products produced infusion) and infusion apparatus to do a hot trace Now the result is introduced below. Infusion pyrogen test 1. From 1970 to 1978 made a total of 245 kinds of infusion of a total of 245 batches, of which a group of pyrogen positive, the remaining negative. 2. The patient reaction, the inventory of the same batch of infusion did a review, a total of 20 batches were not detected pyrogen, some still healthy