论文部分内容阅读
【摘要】目的:测定复方酮康唑乳膏中硫酸新霉素的含量。方法:用2,4-二硝基氟苯作柱前衍生剂,乙腈-三乙胺溶液(pH3.6)(80∶20)为流动相,检测波长为365nm。结果:测定线性范围12.5~200μg/ml[Y=17582.8X+42140,r=0.9995(n=5)]平均回收率为99.7%,RSD=1.39%(n=6)。结论:本法操作简单、快速、灵敏度高。
【关键词】复方酮康唑乳膏 硫酸新霉素 2,4-二硝基氟苯 HPLC
Pre-column-HPLC method derived compound ketoconazole cream in sulfuric acid content of neomycin
LiPu
【Abstract】Objective: To determine the compound ketoconazole cream in the content of neomycin sulfate. Methods: 2,4 - dinitrofluorobenzene for pre-column derivative agent, acetonitrile - triethylamine solution (pH3.6) (80:20) as mobile phase and detection at 365nm. Results: The determination of linear range 12.5 ~ 200μg/ml [Y = 17582.8X +42140, r = 0.9995 (n = 5)] and the average recovery was 99.7%, RSD = 1.39% (n = 6). Conclusion: The method is simple, rapid and sensitive.
【Key words】Compound ketoconazole creamNeomycin sulfate2,4 – dinitrofluorobenzeneHPLC
复方酮康唑乳膏主要用于皮肤浅表真菌染,对手、足、体、股癣有较好的疗效,在OTC用药中有较大的销量,《中国药典》2005年版收载了该品种[1],其中硫酸新霉素含量测定仍使用微生物检定法,该法操作繁琐,且需时较长,重现性较差[2],采用高效液相法测定,但硫酸新霉素在紫外区无特征吸收,故经衍生化,本文采用2,4-二硝基苯(DNFB)[3、4、5]作衍生剂,对复方酮康唑乳膏中硫酸新霉素进行了含量测定。
1仪器与试剂
岛津LC-10AP高效液相色谱仪,SPD-10AP紫外检测器,大连色谱工作站。新霉素标准品(批号:3099310)由中国药品生物制品检定所提供,2,4-二硝基氟苯(江阴暨阳医药化工有限公司), 复方酮康唑乳膏(武汉诺安药业有限公司,批号:2007091);乙腈为色谱纯,其他为分析纯。
2实验方法与结果
2.1色谱条件:色谱柱:Hypersil ODS C18柱(5μm,4.6mm×150mm);流动相:乙腈-三乙胺溶液(量取三乙胺3ml,加水800ml,用磷酸调pH值到3.6)(80∶20);0.8ml/min;柱温38℃;检测波长为365nm,色谱图见图1。
2.2线性关系:精密称取新霉素标准品100mg,置50ml量瓶中,加含3%氯化钠的磷酸盐缓冲液(pH7.8)适量,使溶解并稀释到刻度,摇匀,作为对照品储备液,精密量取适量,分别加上述缓冲液稀释成200.0、100.0、50.0、25.0、12.5μg/ml 5种浓度的溶液。精密量取此5种溶液,分别置50ml量瓶中,各加2,4-二硝氟苯溶液(取2,4-二硝基氟苯0.5g,加无水乙醇50溶解,即得)10ml与三羟甲基氨基甲烷溶液(取三羟甲基氨基甲烷约0.3g,置100ml量瓶中,加水20ml溶解,再用二甲基亚砜稀释到刻度,摇匀,即得)10ml,摇匀。密塞,置60℃水浴中加热50分钟,取出放置10分钟,加乙腈适量,冷却到室温,用乙腈稀释到刻度,摇匀。分别吸取20μl注入色谱仪,记录色谱图,以峰面积Y对浓度X进行线性回归,得线性方程为Y=17582.8X+42140,r=0.9995(n=5),结果表明新霉素在12.5~200.0μg/ml范围内呈良好线性关系。
2.3样品测定方法
2.3.1对照品溶液的制备:精密量取线性关系项下的对照品储备液10ml,置100ml量瓶中,加水稀释到刻度,摇匀。
2.3.2供试品溶液的制备:精密量称取复方酮康唑乳膏4g(约相当于新霉素20mg),置100ml具塞锥形瓶中,加石油醚(沸程90℃-120℃)50ml,超声处理约30分钟,使基质溶解后,转移到分液漏斗中,用含3%氯化钠的磷酸盐缓冲液(pH7.8)提取4次,每次20ml,合并提取液,置100ml量瓶中,加上述缓冲液稀释至刻度[1],摇匀,即成。
3.3测定:精密量取供试品溶液与对照品溶液各5.0ml,分别置50ml量瓶中,各加2,4-二硝基氟苯溶液10ml与三羟甲基氨基甲烷溶液10ml,摇匀,密塞,置60℃水浴中加热50分钟,取出放置10分钟,加乙腈适量,冷却到室温,用乙腈稀释到刻度,摇匀。分别吸取20μl注入色谱仪,记录色谱图,按外标法以峰面积进行计算含量,即得。结果见下表。
2.4适用性试验
2.4.1加样回收率试验:精密量取样品测定项下的供试品溶液10ml,置25ml量瓶中,再精密量取样品测定项下的对照品溶液10 ml、15 ml、20 ml,混合均匀,精密量取混合液5.0ml,照样测定项下的方法,自“分别置50ml量瓶中”起,依法测定,测得回收率分别为99.0%、101.3%、98.8%,平均回收率为99.7%,RSD=1.39%。
2.4.2精密度试验:精密吸取对照品溶液5ml,按样品测定方法测定,连续进样5次,结果RSD为1.48%。
2.4.3稳定性试验:按含量测定项下的方法,对同一批样品,重复进样5次,色谱峰面积的RSD为1.82%(n=5),被测溶液分别放置1、2、4、8、16、24小时再进行测定,结果没有变化。
2.4.4与药典标准比较
结果表明与药典标准方法一致,没有差异。
3讨论
3.1本法试剂存在有峰吸收,为前峰,出峰时间在3-4分钟,样品峰出峰时间在8-10钟,样品峰与试剂峰能很好分离。
3.2新霉素B与新霉素C很好地分离。
3.3处方中酮康唑、丙酸氯倍他索在该检测波长下无吸收,不干扰测定。
3.4本法与药典标准方法一致,但简单灵敏,适合于复方酮康唑乳膏中硫酸新霉素含量测定。参考文献
1中华人民和国药典2005年版二部,436
2苏健.复方酮康唑乳膏中新霉素含量测定方法探讨,西北药学杂志2002,17(3):104
3陈蓉等.HPLC柱前衍生法测定复方新霉素滴耳液中新霉素的含量,中国药品标准,2004,(3):48
4余江南等.两种RP-HPLC柱前衍生法快速测定核糖霉素方法的建立与比较,中国药科大学学报,1996,(1):27
5杨美成等.柱前衍生化HPLC法测定硫酸庆大霉素和硫酸新霉素的含量,中国临床药杂志2004,13(5):288-291
作者单位:416000湖南省湘西州药品检验所
【关键词】复方酮康唑乳膏 硫酸新霉素 2,4-二硝基氟苯 HPLC
Pre-column-HPLC method derived compound ketoconazole cream in sulfuric acid content of neomycin
LiPu
【Abstract】Objective: To determine the compound ketoconazole cream in the content of neomycin sulfate. Methods: 2,4 - dinitrofluorobenzene for pre-column derivative agent, acetonitrile - triethylamine solution (pH3.6) (80:20) as mobile phase and detection at 365nm. Results: The determination of linear range 12.5 ~ 200μg/ml [Y = 17582.8X +42140, r = 0.9995 (n = 5)] and the average recovery was 99.7%, RSD = 1.39% (n = 6). Conclusion: The method is simple, rapid and sensitive.
【Key words】Compound ketoconazole creamNeomycin sulfate2,4 – dinitrofluorobenzeneHPLC
复方酮康唑乳膏主要用于皮肤浅表真菌染,对手、足、体、股癣有较好的疗效,在OTC用药中有较大的销量,《中国药典》2005年版收载了该品种[1],其中硫酸新霉素含量测定仍使用微生物检定法,该法操作繁琐,且需时较长,重现性较差[2],采用高效液相法测定,但硫酸新霉素在紫外区无特征吸收,故经衍生化,本文采用2,4-二硝基苯(DNFB)[3、4、5]作衍生剂,对复方酮康唑乳膏中硫酸新霉素进行了含量测定。
1仪器与试剂
岛津LC-10AP高效液相色谱仪,SPD-10AP紫外检测器,大连色谱工作站。新霉素标准品(批号:3099310)由中国药品生物制品检定所提供,2,4-二硝基氟苯(江阴暨阳医药化工有限公司), 复方酮康唑乳膏(武汉诺安药业有限公司,批号:2007091);乙腈为色谱纯,其他为分析纯。
2实验方法与结果
2.1色谱条件:色谱柱:Hypersil ODS C18柱(5μm,4.6mm×150mm);流动相:乙腈-三乙胺溶液(量取三乙胺3ml,加水800ml,用磷酸调pH值到3.6)(80∶20);0.8ml/min;柱温38℃;检测波长为365nm,色谱图见图1。
2.2线性关系:精密称取新霉素标准品100mg,置50ml量瓶中,加含3%氯化钠的磷酸盐缓冲液(pH7.8)适量,使溶解并稀释到刻度,摇匀,作为对照品储备液,精密量取适量,分别加上述缓冲液稀释成200.0、100.0、50.0、25.0、12.5μg/ml 5种浓度的溶液。精密量取此5种溶液,分别置50ml量瓶中,各加2,4-二硝氟苯溶液(取2,4-二硝基氟苯0.5g,加无水乙醇50溶解,即得)10ml与三羟甲基氨基甲烷溶液(取三羟甲基氨基甲烷约0.3g,置100ml量瓶中,加水20ml溶解,再用二甲基亚砜稀释到刻度,摇匀,即得)10ml,摇匀。密塞,置60℃水浴中加热50分钟,取出放置10分钟,加乙腈适量,冷却到室温,用乙腈稀释到刻度,摇匀。分别吸取20μl注入色谱仪,记录色谱图,以峰面积Y对浓度X进行线性回归,得线性方程为Y=17582.8X+42140,r=0.9995(n=5),结果表明新霉素在12.5~200.0μg/ml范围内呈良好线性关系。
2.3样品测定方法
2.3.1对照品溶液的制备:精密量取线性关系项下的对照品储备液10ml,置100ml量瓶中,加水稀释到刻度,摇匀。
2.3.2供试品溶液的制备:精密量称取复方酮康唑乳膏4g(约相当于新霉素20mg),置100ml具塞锥形瓶中,加石油醚(沸程90℃-120℃)50ml,超声处理约30分钟,使基质溶解后,转移到分液漏斗中,用含3%氯化钠的磷酸盐缓冲液(pH7.8)提取4次,每次20ml,合并提取液,置100ml量瓶中,加上述缓冲液稀释至刻度[1],摇匀,即成。
3.3测定:精密量取供试品溶液与对照品溶液各5.0ml,分别置50ml量瓶中,各加2,4-二硝基氟苯溶液10ml与三羟甲基氨基甲烷溶液10ml,摇匀,密塞,置60℃水浴中加热50分钟,取出放置10分钟,加乙腈适量,冷却到室温,用乙腈稀释到刻度,摇匀。分别吸取20μl注入色谱仪,记录色谱图,按外标法以峰面积进行计算含量,即得。结果见下表。
2.4适用性试验
2.4.1加样回收率试验:精密量取样品测定项下的供试品溶液10ml,置25ml量瓶中,再精密量取样品测定项下的对照品溶液10 ml、15 ml、20 ml,混合均匀,精密量取混合液5.0ml,照样测定项下的方法,自“分别置50ml量瓶中”起,依法测定,测得回收率分别为99.0%、101.3%、98.8%,平均回收率为99.7%,RSD=1.39%。
2.4.2精密度试验:精密吸取对照品溶液5ml,按样品测定方法测定,连续进样5次,结果RSD为1.48%。
2.4.3稳定性试验:按含量测定项下的方法,对同一批样品,重复进样5次,色谱峰面积的RSD为1.82%(n=5),被测溶液分别放置1、2、4、8、16、24小时再进行测定,结果没有变化。
2.4.4与药典标准比较
结果表明与药典标准方法一致,没有差异。
3讨论
3.1本法试剂存在有峰吸收,为前峰,出峰时间在3-4分钟,样品峰出峰时间在8-10钟,样品峰与试剂峰能很好分离。
3.2新霉素B与新霉素C很好地分离。
3.3处方中酮康唑、丙酸氯倍他索在该检测波长下无吸收,不干扰测定。
3.4本法与药典标准方法一致,但简单灵敏,适合于复方酮康唑乳膏中硫酸新霉素含量测定。参考文献
1中华人民和国药典2005年版二部,436
2苏健.复方酮康唑乳膏中新霉素含量测定方法探讨,西北药学杂志2002,17(3):104
3陈蓉等.HPLC柱前衍生法测定复方新霉素滴耳液中新霉素的含量,中国药品标准,2004,(3):48
4余江南等.两种RP-HPLC柱前衍生法快速测定核糖霉素方法的建立与比较,中国药科大学学报,1996,(1):27
5杨美成等.柱前衍生化HPLC法测定硫酸庆大霉素和硫酸新霉素的含量,中国临床药杂志2004,13(5):288-291
作者单位:416000湖南省湘西州药品检验所