1998年6月1日,临23井1#DPC—60型天然气压缩机由于排出温度异常,一级排出温度超过90℃,二级吸入温度超过70℃,二级排出温度超过120℃,热继电器跳闸停机。6月3日开机,六七分钟后又因热继电器跳闸停机待处理。对造成温度高的原因进行分析,排除
June 1, 1998, Pro 23 Well 1 # DPC-60 natural gas compressor due to the abnormal discharge temperature, a discharge temperature exceeds 90 ℃, the secondary suction temperature exceeds 70 ℃, the secondary discharge temperature exceeds 120 ℃, the thermal relay Trip down. June 3 boot, six or seven minutes after the trip due to thermal relay shutdown pending. Analysis of the causes of high temperature, ruled out