论文部分内容阅读
目的了解医院环境卫生学监测状况,为合理制定医院感染防控措施提供依据。方法 2011-2014年对灭菌后物品、物体表面、空气、使用中消毒液、医务人员手和透析用水做细菌培养,分析监测结果。结果 4年共监测样品8 924份,总合格率为92.99%。2011-2014年合格率分别为89.72%、92.44%、94.86和95.45%,合格率呈逐年提高趋势。不同监测项目中,使用中消毒液合格率最高,医务人员手合格率最低。结论医院环境卫生学监测合格率逐年提高,但也存在薄弱环节,应该加强手卫生宣传,不断提高医院消毒质量。
Objective To understand the status of hospital environmental hygiene monitoring and provide the basis for the reasonable formulation of prevention and control measures of nosocomial infection. Methods From 2011 to 2014, the bacteria were cultured in the sterilized articles, the surface of the object, the air, the disinfectant in use, the hand of the medical staff and the dialysis water, and the monitoring results were analyzed. Results A total of 8 924 samples were monitored in 4 years, with a total pass rate of 92.99%. The qualification rates in 2011-2014 were 89.72%, 92.44%, 94.86 and 95.45%, respectively, and the passing rate showed an increasing trend year by year. Different monitoring items, the use of disinfectant in the highest pass rate, the lowest pass rate of medical staff. Conclusion The passing rate of environmental sanitation monitoring in hospitals has been increasing year by year, but there are also weak links. Hand hygiene publicity should be strengthened to continuously improve the quality of hospital disinfection.